Products
10 ~ 3000m³/H 0~ 200Pa Air Volume Measurement System For A.C. Electric Ventilating Fans
Products Description
10 ~ 3000m³/h 0 ~ 1200Pa Air Volume Measurement System for A.C. Electric Ventilating Fans
Overview:
This air volume measurement system is mainly designed according to GB/T14806-2017 and GB/T1236-2017 , which can accurately measure the air volume, wind pressure, power, full pressure and other parameters for ventilating fans; pressure test range is 0 ~ 1200Pa, air volume range is 10 ~ 3000m3 / h.
Standards:
Can be designed according to the following standards:
► GB/T14806-2017
► GB/T1236-2017
► Other international standards
Types of UUT :
A.C. Electric Ventilating Fans
Technical Conditions:
Test items: air volume, wind pressure, temperature, humidity, atmospheric pressure, etc.
Characteristic curve chart: According to customer requirements, draw the test curve of the fan under different air volume and wind pressure.
detect ability
10~3000
(m3/h)
0~1200
(Pa)
-10~80
(℃)
0~1000
(W)
80~120
(kPa)
Technical Characteristics and Advantages:
Test items
Air volume
Pressure
Temperature
Humidity
Electrical parameters
Atmospheric pressure
0~100%(RH)
Measurement accuracy
Not less than ±1%
±0.1%
±0.15℃
±2%RH
0.1%
±0.2%
Brand
homemade
Rosemont
Vaisala / Vaisala
Yokogawa(not less than DC,0.1Hz~100kHz)
Domestic
Test items
Pressure difference
current
efficiency
rotate speed
Measurement accuracy
±0.1%
0.5%
±1%
±5(rpm)
Brand
Rosemont
Yokogawa
measured value