Products
IEC60335-2-24 Household Appliance Refrigerated Door Endurance Test Machine
Products Description
IEC60335-2-24 Household Appliance Refrigerated Door Endurance Test Machine
2 pcs
The Vacuum suction cup sucks on the door tightly, then servo motor drives the manipulator back and forth, the speed, angle, test cycles can be set and displayed on the touch screen
Right or Left
0-90°, can be preset
Test Principle and Equipment Structure For Refrigerated Door Endurance Test Machine:
Test principle: The on/off actions of the interlocking device are controlled through developed program, the manipulators are driven by servo motor to reciprocating open and close the door(s) at a certain speed with vacuum suction cup sucking on the door, thus, to verify the stability of the interlocking device.
Structure: The equipment combines of electrical control cabinet (including load voltage regulating device), frame, manipulator and vacuum suction cups.
Product Information For Refrigerated Door Endurance Test Machine:
Standard:IEC60335-2-24:2017 “Household and similar electrical appliances-Safety-Part2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice-makers, IDT”.
Application:It is used to test the durability of the interlocking device of the door for vertical refrigerators, also used to assist other tests for door repeated opening and closing operations of refrigerators, such as the defrost test and refrigerant leakage test.
Test sample:Refrigeration appliances (refrigerators with 2 vertical doors at the same side or 1 door).
Technical Parameters For Refrigerated Door Endurance Test Machine:
Power Supply
AC220V±10%/ 50 Hz-60 Hz, power 3KW
Test Station
Single station
Control Mode
PLC intelligent integrated control, 7-inch humanized touch interface operation
Drive Mode
Servo motor drive
Available Sample Type
Sample with 2 vertical doors at the same side or 1 door
Clamping Method for Door
Vacuum suction cup, pneumatic
Number of vacuum suction cups
The distances of the two vacuum suction cups can be adjusted, to match the different height or suction positions of two doors
Door Open and Close Method
Door Open and Close Directions
The suction cups can be installed on the right side or left side, and there is an expand base plate which can be connected on the right side or left side of the base plate, thus to match the right door or left door opening requirements.
Door Opening or Closing Speed
0-360°/s, can be preset
Door Opening or Closing Angle
(If you have another required angle, please let us know)
Test Times
0-999999 times, can be preset
Load Voltage
0-250V, adjustable
Test Contents
Refrigerator door interlocking device endurance test (IEC60335-2-24:2017)
Safety Protection
Power
Leakage protection, overload and short circuit protection
Motor
Overload, short circuit protection
Equipment dimensions: approx.: (W*D*H) 1500 * 1300 * 2000 (mm)
Equipment weight: 250kg