Products Description
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter
System introduction:
The air enthalpy calorimeter test chamber consists of an indoor side chamber (A chamber) and an outdoor side chamber (B chamber). The refrigerating capacity, heating capacity and other performance of the air conditioner are tested by testing the parameters of temperature, pressure and electrical performance of the laboratory. The device can be used to test the performance of various window type, split type, independent type, ceiling box type and duct type air conditioners, and can also be used for related tests and extended tests under other standard operating conditions to meet the needs of product sampling inspection and product development. The laboratory has two stations, can simultaneously test two sets of not more than 30KBtu single-phase prototype (to ensure that the total is not greater than 60K BTU), if only test a prototype once, the prototype can reach 60K BTU, but should not be greater than 60K BTU.
Testing items:
►Rated cooling capacity (T1, T2, T3).
►Rated heating capacity (high, low, ultra low)
►Airflow
►Dehumidifying capacity
►Input power
► EER(COP)
►Frequency
►electric current
►Voltage
Types of UUT and environment:
Unit under test (UUT) type
- Split type
- Windowed
- Freestanding
- Ceiling Box
- Duct type
- Inverter air conditioner
► Measurement range of UUT
- Test Capability Range:
- Total cooling capacity: 6000 ~ 60000 Btu / h
Cooling capacity of station A: 6000 ~ 60000 Btu / h
Cooling capacity of station B: 6000 ~ 30000 Btu / h
- Heating capacity: 6000 ~ 60000 Btu / h
Heating capacity of station A: 6000 ~ 60000 Btu / h
- Airflow Range
- Air flow rate A: 300 ~ 4000 m3 / h
Air volume B: 200 ~ 2000 m3 / h
- Overall Dimensions: Window: Width: Up to 1000 mm Depth: Up to 800 mm Height: Up to 1000 mm
Split type: width: less than 1000 mm depth: less than 500 mm height: less than 2000 mm
- Electrical parameters
- Single-phase power: 0 ~ 5 kW
Single phase voltage: 0 ~ 300 V
Single phase current: 0 ~ 20 A
Frequency: 50 / 60 Hz
- Power factor: 0 ~ 1
Major test conditions
No
Testing Item
Indoor side(℃)
Outdoor side(℃)
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
1
Rating Cooling
T1
27
19
35
24
T2
21
15
27
19
T3
29
19
46
24
2
Maximum Cooling
T1
32
23
48
32
T2
27
19
35
24
T3
32
23
52
31
3
Freeze-up
T1
21
15
21
15
T2
21
15
10
8
T3
21
15
21
15
4
Minimum Cooling
21
15
18
12
5
Enclosure Sweat
27
24
27
24
6
Rating Heating
High
20
15
7
6
Low
20
15
2
1
Extra Low
10
8
-5
-6
7
Maximum Heating
27
19
24
18
8
Minimum Heating
20
15
-7
-8
9
Automatic Defrost
20
12
2
1
KingPo is a diversified high-tech enterprise integrating testing equipment, scientific research and teaching equipment, all kinds of non-standard customized equipment, and integrating independent R & D design, production and sales, installation and commissioning, after-sales maintenance. Company technical staff has accumulated rich practical experience.