IEC 60065 2014 Clause 9.1.1.3 Test Probe 18 Ф8.6mm Children Finger Probe

MOQ:1
Price:Negotiable
StandardPackaging:AluminiumBox
DeliveryPeriod:3Days
PaymentMethod:L/C,T/T,WesternUnion,MoneyGram
SupplyCapacity:100setspermonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP2210-12

Applied Standard:IEC 60065

Applied Clause:Clause 9.1.1.3

Finger Probe Diameter:Ф8.6mm

Finger Probe Length:57.9mm

Probe Material:Stainless Steel

Handle Material:Nylon

Axes Of Joints Distance:19.3mm

Extension Handle Diameter:Ф38.1±0.3mm

Minimum Order Quantity:1

Price:Negotiable

Packaging Details:Aluminium Box

Delivery Time:3 Days

Payment Terms:L/C, T/T, Western Union, MoneyGram

Supply Ability:100 sets per month

Highlight:8.6mm Test Probe, Children Finger Test Probe, Stainless Steel Test Probe


Product Description

 

IEC 60065:2014 clause 9.1.1.3 Test Probe 18 Ф8.6mm Children Finger Probe

 

Product Overview:

This probe conforms to the standard requirements of IEC 60065:2014 clause 9.1.1.3, IEC 61032 figure 12 test probe 18 and etc. This probe is intended to simulate access to hazardous parts by children of more than 36 months and less than 14 years.

 

Probe Dimension:

Hemispherical radius (mm) R4.3±0.05
Finger probe diameter (mm) Ф8.6±0.1
Finger probe length (mm) 57.9±0.15
Axes of joints distance (mm) 19.3
Collar diameter (mm) Ф38.4±0.3
Collar length (mm) 101.6±0.3
Extension handle diameter (mm) Ф38.1±0.3
Extension handle length (mm) 451.6±0.8
Finger probe material (mm) Stainless steel
Collar and handle material (mm) Nylon
 
Operation:

Please refer to the relevant standards.

Take IEC 60065:2014 clause 9.1.1.3 as an example:

The test is repeated using small finger probes according to test probes 18 and 19 of IEC 61032:1997. This does not apply if the intended conditions of use prevent the apparatus from being accessed by children.

 

The test probe doesn’t have built-in force, if specific applied force required, the test probe should work together with a force gauge (use a force gauge to apply required force on the end of the probe directly).

 

The probe is equipped with a connection cable, for verifying whether the LIVE PARTS touched, recommended to work with our anti-shock probe experiment device or a 40~50V voltage indicator. Connect the connection cable of the probe with one terminal of the anti-shock probe experiment device, and then use an additional cable to wire the LIVE PART of specimen with the other terminal of the anti-shock probe experiment device. Showing as following reference picture:

 