Integrated Electrical Appliance Door Endurance Testing Equipment IEC 60335

MOQ:1
Price:Customized
StandardPackaging:Plywood
DeliveryPeriod:1Month
PaymentMethod:L/C,T/T,WesternUnion,MoneyGram
SupplyCapacity:5SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP1401B

Applied Standards:IEC 60335 Series

Applied Samples:Electrical Appliances

Test Stations:2 Station

Control Method:PLC Intelligent Integrated Control

Display Method:10\" Touch Screen

Opening / Closing Speed:0-360°/s(1.5m/s)

Opening / Closing Angle:0-130°

Opening / Closing Force:0-200N

Minimum Order Quantity:1

Price:Customized

Packaging Details:Plywood

Delivery Time:1 Month

Payment Terms:L/C, T/T, Western Union, MoneyGram

Supply Ability:5 Sets Per Month

Highlight:IEC 60335 Door Endurance Testing Equipment, Appliance Door Endurance Testing Equipment


Product Description

 

Integrated Electrical Appliance Door Endurance Testing Equipment IEC 60335

 

Product information:

IEC60335-2-4:2008 “Household and similar electrical appliances-Safety-Part2-4: Particular requirements for spin extractors” clause 18

IEC60335-2-11:2008 “Household and similar electrical appliances-Safety-Part2-11: Particular requirements for tumble dryers” clause 20.101

IEC60335-2-7:2016 “Household and similar electrical appliances-Safety-Part2-7: Particular requirements for washing machines” clause 18 and 22.104

IEC 60335-2-5 household and similar electrical appliances – safety: part 2-5: particular requirements for dishwashers, clause 23.3.

IEC 60335-2-25 household and similar electrical appliances – safety: part 2-25:particular requirements for microwave ovens, including combination microwave ovens, clause 18.

 

Application:It is used to test the durability of the interlocking device of washing machine door or lid, and the force test when the interlock is actuated, so as to verify the reliability of the interlocking device; also used to assist other tests for repeated opening and closing operations of the washing machine door or lid.

 

Test sample:Electric tumble dryer, electric washing machine (including pulsator and tumble type single phase ≦ 250V, other ≦ 480V), spin extractors (Load capacity ≦10kg, tumble line speed ≦50m/s, single phase ≦250V, other ≦480V), electric dishwasher, (single phase ≦ 250V), Microwave ovens.

 

Structure:

The equipment combines of electrical control cabinet (including load voltage regulating device), frame and manipulators. There are two testing station, one is for tumble washing machine with door, the other is for pulsator washing machine with lid, the two workstations can process testing independently.

Equipment dimensions: approx.: (W*D*H)2500 * 1300 * 1300 (mm)

Equipment weight: 300kg

 

Technical parameters:

 

Power Supply AC220V±10%/ 50 Hz, power 6KW (can be customized)
Test Stations

2 independent stations, one is for tumble washing machine with door, the other is for pulsator washing machine with lid

Or 2 stations for tumble washing machines (optional)

Control Method PLC intelligent integrated control, 7-inch humanized touch interface operation
Drive Mode Servo motor drive
Clamping Method for Specimen Vacuum suction cup, pneumatic
Door/Lid Opening or Closing Speed 0-360°/s(1.5m/s), can be preset
Door/Lid Opening or Closing Angle 0-130°,can be preset
Test Times 0-999999times, can be preset
Door/Lid Opening or Closing Force 0-200N, can be preset (the opening force value is only for the pull test when the interlock device is actuated to lock the door)
Load Voltage 0-250V, adjustable
Auxiliary Action Mechanism Washing machine starts pressing cylinder (can be customized)
Test Contents

IEC60335-2-4:2008 “Household and similar electrical appliances-Safety-Part2-4: Particular requirements for spin extractors” clause 18

IEC60335-2-11:2008 “Household and similar electrical appliances-Safety-Part2-11: Particular requirements for tumble dryers” clause 20.101

IEC60335-2-7:2016 “Household and similar electrical appliances-Safety-Part2-7: Particular requirements for washing machines” clause 18 and 22.104

IEC 60335-2-5 household and similar electrical appliances – safety: part 2-5: particular requirements for dishwashers, clause 23.3.

IEC 60335-2-25 household and similar electrical appliances – safety: part 2-25: particular requirements for microwave ovens, including combination microwave ovens, clause 18.

IEC 60335-2-9 clause 23.3 flexing for appliance can opened in 2 position

IEC 60335-2-24 clause 23.3 flexing test for conductors that are flexed

Safety Protection
Power Leakage protection, overload and short circuit protection
Motor Overload, short circuit protection
 
 
 