Products
5 In 1 Desktop Electrical Safety Compliance Test Equipment LCD Display PLC Control
Products Description
5 in 1 Desktop Electrical Safety Compliance Tester
1~2000MΩ
Upper limit: 0 to 2000 MΩ
Upper limit:
Upper limit: 0.05~20.00mA
Upper limit: 3~6000W
Connection with Sample
Standards & Clauses:
IEC60884-1:2013 “Plugs and socket-outlets for household and similar purposes- Part1: General requirements”
IEC60335-1:2016 “Household and similar electrical appliances-Safety-Part1: General requirements”
IEC60950-1:2013 “Information technology equipment-Safety-Part1: General requirements”
IEC60065:2014 “Audio, video and similar electronic apparatus-Safety requirements”
Samples and Restrictions:
Household appliances, electrical accessories, lamps, etc.
Application:
Various types of home appliance manufacturers, as well as institutions that conduct home appliance safety testing and certification, research institutes
Test Contents:
AC withstand voltage, insulation resistance, grounding resistance, leakage current, power test
Features:
■ 5.7” Blue background LCD display, data display is intuitive and clear
■ Meet standard requirements of CCC,IEC,EN,VDE,BS,GS,UL, etc.
■ Industrial computer system is optional, which supports to add barcode scanner to achieve automatic control and data entry, build production data management platform, and can be integrated into production management system
■ Variable frequency power supply is optional, which supports to form an automatic test system, realize automatic adjustment of test power supply output, without manual intervention, to ensure accurate test results
■ 15 sets memory of test condition, 8 test steps in each group, specifications of each group can be set separately, easy for query
■ Fast speed: The control core of the test instrument adopts ARM high-speed processor, the data processing is comprehensive and fast
■ Withstand voltage can be ramped up and ramp downed, has upper and lower limit alarm functions
■ Adopts digital closed loop feedback control, and fully automatic pressure regulation mode, the output voltage/current is automatically corrected and is not affected by external grid fluctuations, ensuring the accuracy of the test
■The grounding resistance test can select voltage mode or resistance mode, to meet different national/industry standards
■ Built-in leakage current body network as per IEC 60990 figure 4, can customize other body networks - optional
■ Standard PLC remote control, RS232 and alarm light interfaces
Technical Parameters:
AC Withstand Voltage Test
Output voltage setting range / accuracy
AC 200~5000V, ± (3% × setting + 5 words)
Breakdown current measurement range / accuracy
0.10~25.00mA, ± (3% × reading + 5 words)
Breakdown current preset alarm range
Upper limit: 0.10~25.00mA; lower limit: 0.00~5.00mA
Test time range / resolution
1~300s, 1s/step
Insulation Resistance Test
Output voltage setting range / accuracy
DC 500/1000V, ± (3% × reading + 5 words)
Insulation resistance measurement range / accuracy
≤100MΩ: ± (5% × reading + 3 words)
>100 MΩ: ± (8% × reading + 8 words)
Insulation resistance alarm setting range
Lower limit: 1 to 2000 MΩ
Test time range / resolution
1~300s, 1s/step
Grounding Resistance Test
Ground current output range / accuracy
AC 5.0~30.0A, ± (3%×setting+5 words)
Ground resistance measurement range / accuracy
10.0 to 600 mΩ, ± (3% × reading+ 5 words)
Grounding resistance alarm setting range
5~10A:10.0~600mΩ;
11~25A:10.0~300mΩ;
26~30A:10.0~200mΩ;
Lower limit:
0.0~100mΩ
Test time range / resolution
1~60s, 1s/step
Leakage Current Test
Output voltage
1.06 times rated voltage
Leakage type setting
Dynamic leakage, static leakage. Default leakage current body network as per IEC 60990 figure 4 built-in, other body network can be customized. If have special requirements, pls specific which body network you prefer, cost may be different
Output voltage measurement range / accuracy
AC 50 ~ 280V, ± (3% ×reading + 2 words)
Leakage current measurement range / accuracy
0.05~20.00mA, ± (3% ×reading + 10uA)
Leakage current setting alarm range
Lower limit: 0.01~5.00mA
Test time range
1~300s, 1s/step
Power Test
Output voltage
1.0 times rated voltage
Output voltage measurement range / accuracy
AC 50~280V, ± (0.5% × reading + 2 words)
Output current measurement range / accuracy
AC 0.2~30.00A, ± (0.5% × reading + 2 words)
Active power measurement range / accuracy
30~6000W, ± (0.5% × reading + 5 words)
Power setting alarm range
Lower limit: 0~6000W
Test time range / resolution
1~300s, 1s/step
General
Interfaces
RS232, alarm light interface
Standard Accessories
Power cord * 1, 30A test clamp * 1, test box * 1, test power input line * 1, fuse * 1
Optional Accessories
Alarm light, foot switch
Equipment Dimensions (MM)
W 435W * H 150H* D 550D