Products
IEC60309-1 Clause 20 Vehicle Connector And Plug Breaking Capacity Test Machine
Products Description
IEC60309-1 Clause 20 Vehicle Connector and Plug Breaking Capacity Test Machine
Product Information:
The Vehicle Connector and Plug Breaking Capacity test machine conforms to the standard requirements of IEC60309-1 clause 20 and clause 21, IEC62196-1 clause 7.11 and clause 7.12 and etc.
It is used to verify whether electrical accessories such as electric vehicle charging interfaces, industrial plugs, socket-outlets and couplers can withstand the mechanical, electrical and thermal stresses that occurred during normal operation without excessive wear or other harmful effects.
Technical Parameters:
Appliance coupler/charging interface breaking capacity test
Appliance coupler / charging interface normal operating life test
Applied standard
IEC IEC60309-1
Applied clause
Clause 20 and 21
Test station
Single
Control method
PLC intelligent integrated control, with color humanized touch screen
Drive mode
Servo motor drive
Sample clamping method
Mechanical clamping, the position of clamping point can be adjustable along the 3-axis fixture
Linear stroke
0-100mm, can be preset (the spacing between test plug and test socket≥ 50mm)
Conduction time
0-99.9s, can be preset (electrical contact should be maintained no more than 4s, no less than 2s)
Speed of Insertion and Separation
0-0.85m/s can be preset, default(0.8±0.1)m/s)
Test frequency
0-10 cycles/min, can be preset (3.75cycles/min=7.5 stoke/min)
Test cycles
0~999999 cycles, can be preset
Load power
External, providing standard required voltage, current and power factor, the load cabinet is optional
Optional load cabinet
Note: only with AC load cabinet, 0-70A, voltage 0-300V
Test contents
Detection function
An open circuit alarm can be realized during testing under load, and the cycles can be recorded real in time.
Safety protection
Ground protection, short circuit protection