Leakage Current Tester Electrical Appliance Safety Testing Equipment

MOQ:1
Price:Negotiable
StandardPackaging:CartonBox
DeliveryPeriod:20Days
PaymentMethod:L/C,T/T,WesternUnion,MoneyGram
SupplyCapacity:50setspermonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP9620X

Test Contents:Leakage Current Test

Applied Standard:IEC60335.1, UL60335.1, Etc.

Test Input Voltage:30-300V AC Single Phase

Test Input Current:20A AC MAX

Leakage Current Range:50-6000uA

Leakage Current Resolution:1uA

Minimum Order Quantity:1

Price:Negotiable

Packaging Details:Carton Box

Delivery Time:20 Days

Payment Terms:L/C, T/T, Western Union, MoneyGram

Supply Ability:50 sets per month

Highlight:UL60335.1 Electrical Appliance Safety Testing Equipment, 6000uA Appliance Safety Testing Equipment, 50K Leakage Current Tester


Product Description

 

Leakage Current Tester Electrical Appliance Safety Testing Equipment

 

Product information:

 

■ Meet the electrical safety general test requirements of IEC60335.1, UL60335.1, GB4706.1, etc.
■Built-in common human body simulation impedances, different simulation impedance standard cards can be selected according to different standards, default come with network as per IEC 60335-1, other networks are optional.
■ Upper limit preset, automatic reminder of alarm message, intelligent memory analysis function, system self-check function, automatic protection function.

■ 16*2LCD display

■The instrument has a software calibration function for simplify parameter calibration.

 

Technical Parameters:

 

Model SN9620X
Input voltage 220Vac±10%
Input power 50/60Hz±5%
Fuse Fuse 0.5A/250V
Leakage current
Test input voltage 30-300V AC Single phase
Test input current 20A AC MAX
Voltage display range 30-300V AC
Voltage display resolution 1V
Voltage display accuracy ± (2% setting+3V)
Leakage current range 50-6000uA
Leakage current resolution 1uA
Leakage current accuracy ± (2% reading+30uA)
Built-in human network Default as per IEC 60335-1, other networks are optional
Test time range 1.0-2.0-999.9s , resolution 0.1s, set 1s only to test the leakage of firewire
Function parameters
Display 16*2 blue screen character LCD display
Communication Interface RS232(optional)
Calibration method Software calibration
Working environment 0-40℃, 20-80%RH
Dimensions & weight 280mm(W)×89mm(H)×370mm(D), approx. 15kgs
Accessories Power cord × 1, test clip × 2, fuse× 1
 

Calibration required instrument:

1. 50-300V adjustable test power source

2. 50K block resistor

3. Digital multi-meter with a 20mA AC.

 

Calibration preparation:

Set the upper limit current alarm value of the tester SN9620X to the full scale, and the lower limit to 0. The current calibration within the measuring range can be performed and avoid the over current test stop.

 

Calibration connection:

 

 