IEC60309-1 2012 Vehicle Testing Equipment 8 Channels Connector Temperature Rise 0 To 400°C Test System

MOQ:1
Price:Customized
StandardPackaging:Plywood
DeliveryPeriod:30Days
PaymentMethod:L/C,T/T
SupplyCapacity:20SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KPQC1006

Temperature Measurement Range:0~400°C

Applied Standard:IEC62196-1:2014 IEC60309-1:2012

Output Voltage:AC 5V

Temperature Data Recording:By Computer Or U Disk Storage

Output Current:Max. 400.0A

Test Content:Temperature Rise

Test Channels:8 Channels

8 Channels:PLC

Minimum Order Quantity:1

Price:Customized

Packaging Details:Plywood

Delivery Time:30 Days

Payment Terms:L/C, T/T

Supply Ability:20 Sets Per Month

Highlight:IEC60309-1 2012 Vehicle Testing Equipment, 8 Channels Connector Vehicle Testing Equipment


Product Description

 

IEC60309-1 2012 8 Channels Connector Temperature Rise 0 To 400°C Test System

 

Equipment Overview:

 

The equipment provides a low voltage test voltage to the sample by simulating the normal use environment, and collects the temperature rise within a certain period of time and compares it with the standard requirements.
It is used for testing the temperature rise of plugs and sockets of charging ports interface after passing the rated current, assessing the heating of the surface of the electrical accessories when the load current is switched on and whether the temperature rise of the terminals complies with the standard requirements.
Can be used to test electric vehicle charging ports, industrial plugs and sockets and couplers.

 

Structures & Characteristics:

The temperature rise test system consists of a voltage regulator, a current transmitter, a PLC programmable controller, a current transducer, a touch-type human-machine interface and a movable chassis. It can stabilise the output test current, eliminating the effects on the test current due to fluctuations in the supply voltage, changes in the resistance of the connecting wires or copper rods or test samples, and improving the accuracy of the test results. The power supply has the advantages of low loss, high efficiency, easy operation, and complete control and detection functions. The touch screen displays the current value and temperature value of each temperature measurement point at any time. Temperature values are recorded every 2 seconds and a report is generated, which can be stored on a USB stick or copied to a PC for viewing and printing.

 

Technical Parameters:

 

Temperature Measurement Point

8 channels

Operation Method

Color humanized touch interface

Output Constant Adjustable Current

AC 0.50~50.00~400.0A(Level 1, can be set)

Output Current Mode

Continuous/ Intermittent

Load Test Output Voltage

Below AC 5V

Current Resolution

0.1A

Ammeter Accuracy

±1%±3 bytes

Voltmeter Accuracy

±1%±3 bytes

Continuous Mode Test Time

0.01~99.99 hours

Intermittent Mode Test Time

0.01~99.99 hours

Intermittent Mode Test Cycles

1~99999 cycles, automatic shutdown when the test cycles reach to the preset value

Temperature Measurement Range

0~400°C, accuracy 0.3% reading + 1°C; resolution: 0.1°C

Temperature Data Acquisition

Configure RS232 communication interface and data record interface

Temperature Scanning Speed

1 to 255 seconds all channels

Temperature Data Record

The data can be stored U disk

Temperature Measuring Thermocouple

OMEGA USA Model T 30AWG Filament Thermocouple, 2 Metres, 8 pcs.

Power Supply

Single phase AC220V±10%, 50/60Hz, 3KVA

Equipment Dimensions and weight

Approx. L 800mm* W 680mm* H1610mm, 125KG

 

 

Tags: