Products
IEC 62196-1 2020 Electric Vehicle Connectors Temperature Rise Test Equipment
Products Description
IEC 62196-1: 2020 Electric Vehicle Connectors Temperature Rise Test Equipment
Product Overview For Electric Vehicle Connectors Temperature Rise Test Equipment:
This temperature rise test system meets the standard requirements of IEC 62196-1: 2020 clause 24, IEC 60309-1: 2012 clause 22, etc.
It is suitable for detecting the temperature rise test after the charging pile interface plug and socket pass the rated current, and assessing the heating of the surface of the electrical accessories when the load current is connected, and whether the temperature rise of the terminal meets the requirements of the standard.
Equipment Principle For Electric Vehicle Connectors Temperature Rise Test Equipment:
The temperature rise test system consists of an electric voltage regulator, a current transducer, a PLC programmable controller, a current sensor, a humanized touch screen and a movable chassis. It can stably output the test current, and eliminate the influence to the test current caused by the fluctuation of the power supply voltage, the connecting wire or the copper bar, and the resistance value of the sample, and improve the accuracy of the test result. The power supply have functions of low loss, high efficiency, easy operation, complete control and detection. The touch screen can display the current value and the temperature values of each temperature measurement points in real time. The temperature value can be recorded every 2 seconds and report can be generated, which can be stored in a USB flash drive and copied to a computer for viewing and printing.
Technical Parameters For Electric Vehicle Connectors Temperature Rise Test Equipment:
Temperature Measurement Point
8 channels
Operation Method
Color humanized touch interface
Output Constant Adjustable Current
AC 0.50~50.00~400.0A(Level 1, can be set)
Output Current Mode
Continuous/ Intermittent
Load Test Output Voltage
Below AC 5V
Current Resolution
0.1A
Ammeter Accuracy
±1%±3 bytes
Voltmeter Accuracy
±1%±3 bytes
Continuous Mode Test Time
0.01~99.99 hours
Intermittent Mode Test Time
0.01~99.99 hours
Intermittent Mode Test Cycles
1~99999 cycles, automatic shutdown when the test cycles reach to the preset value
Temperature Measurement Range
0~400°C, accuracy 0.3% reading + 1°C; resolution: 0.1°C
Temperature Data Acquisition
Configure RS232 communication interface and data record interface
Temperature Scanning Speed
1 to 255 seconds all channels
Temperature Data Record
The data can be stored U disk
Temperature Measuring Thermocouple
American Omega T-type 30AWG filament thermocouple, length 2 meters, a total of 8 pieces
Power Supply
Single phase AC220V±10%, 50/60Hz, 3KVA
Equipment Dimensions and weight
Approx. L 800mm* W 680mm* H1610mm, 125KG