IEC 62133 Lithium Battery Test System with Explosion Proof Chamber
Products Description
IEC 62133 Lithium Battery Test System with Explosion Proof Chamber
Product information For Lithium Battery Test System with Explosion Proof Chamber:
Battery overcharge and over-discharge explosion-proof box is mainly used for battery overcharge and over-discharge, charge and discharge test, the battery is placed in the explosion-proof box, external charge and discharge test equipment, the operator and the instrument for protection.
Technical Parameters For Lithium Battery Test System with Explosion Proof Chamber:
Test chamber size per layer: 500*500*500 (D*W*H),( Three zones structure, can be customized.
Outer box size: 710*780*2060mm (W*D*H)
Outer box: 1.5MM thick cold-rolled plate and high-temperature double-sided baking paint treatment.
Inner box: SUS # 304 stainless steel, thickness 1.00MM thick.
Single door, double door, inner box door is made of stainless steel, and add silicone strip to tighten, open visual observation window on the front
The door is connected to the box by strong hinges, while each door adds an explosion-proof hinge, the right end of the chain is fixed in the latch side to prevent the explosion-proof box and door separation, effectively protecting the safety of testers
Each layer of the box is installed with lighting device, convenient to observe the specimen.
Individual test panels to control lighting and exhaust in each test chamber.
Equipment size
Equipment Material
Box load-bearing capacity
The bottom load capacity is not less than 150KG, the second/third layer load capacity is not less than 50KG
Equipment box door
Observation Window
Double tempered glass, tempered glass thickness of 10MM, double tempered glass between the addition of steel wire grid in the explosion can do traction, while preventing the glass explosion when the glass splash injury testers situation. Observation window sealing using 3M glass adhesive for sealing
Box protection
The test chamber is fully laminated with Teflon tape inside to effectively prevent corrosion, insulation, flame retardant and easy to clean.
Wire loading port
Each layer of the box on the left and right sides of each open a round loading line mouth, Ф50MM diameter, easy to test the connection line through
Exhaust
Each layer of the box back are installed with exhaust fans and leave the exhaust guide (diameter 100MM), can be connected to the laboratory powerful extraction fan
Lighting
Heat insulation protection
Insulation design between each layer can avoid mutual influence test.
Weight
Approx 200kg
Power supply