IEC 61242-2015 Temperature Rise Test Apparatus For Cable Reels For Household Testing

MOQ:1Set
Price:Negotiable
StandardPackaging:PlywoodCase
DeliveryPeriod:30days
PaymentMethod:T/T
SupplyCapacity:10Sets/Month

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate(cost additional )

Model Number:KP2119C

Control Method:PLC Control

Operation:Touch Screen Operation

Test Current:0.1-20A

Test Voltage:0-250V Adjustable

Current Accuracy:±0.5%FC±2d

Voltage Accuracy:±0.5%FC±2d

On-off Cycles:0-9999 Times

Minimum Order Quantity:1 Set

Price:Negotiable

Packaging Details:Plywood Case

Delivery Time:30 days

Payment Terms:T/T

Supply Ability:10 Sets / Month

Highlight:Cable Reels Temperature Rise Test Apparatus, Household Testing Temperature Rise Test Apparatus


Product Description

 

IEC 61242-2015 Temperature Rise Test Apparatus For Cable Reels For Household Testing

 

 

Product information:

 

Standard: GB/T19637-2017 "Electrical accessories - Cable reels for household and similar purposes" Chapters 19 and 20

IEC61242-2015 "Electrical accessories - Cable reels for household and similar purpose" clause 19 and 20

DIN VDE 0620-1:2021 "Plugs and socket-outlets for household and similar purposes - Part 1: General requirements on fixed socket-outlets" clause 19

BS 1363-1:2016+A1:2018 clause 16 and 25.1.1 and 27.2

 

Sample and restrictions: Household electrical plugs and sockets (BS and VDE) and cable reels for household and similar purposes.

 

Test purpose: Test the temperature rise of household electrical plugs and sockets (BS and VDE) and cable reels for household and similar purposes in working state and under overload condition.

 

Test principle: Use the voltage regulator to adjust the voltage so that it can supply power at the rated voltage, and adjust the internal resistance of the equipment to reach the output of the rated current or 1.5 times the rated current (under overload condition test). Measure the temperature rise after the standard power-on time. The equipment can control the power-on time, with real-time display of current and voltage, and can perform on-off cycle (on-off) test. Optional temperature recording function.

 

Equipment structure and features: PLC control, touch screen operation, voltage and current can be displayed on the touch screen. If the temperature recording function is selected, the touch screen can collect and display the temperature, temperature rise and temperature-time curve.

 

Equipment dimensions approximately: 600×600×600 (mm) W×D×H, Equipment weight: 100kg

 

Power supply: AC220V±10%/50-60Hz, operating temperature 0-40℃, humidity 30%-90%;

 

Usage environment: Power supply: AC220V±10%/50-60Hz, operating temperature 0-40℃, humidity 30%-90%;

 

Technical parameters:

 

Model SN2119C SN2119D SN2119F
Control and operation PLC control, touch screen operation PLC control, touch screen operation PLC control, touch screen operation
Test current

0.1-20A, ammeter display

Accuracy ±0.5%FC±2d

0-20A, with current input module, current touch screen display 0-20A, with communication module, current touch screen display
Test voltage

0-250V adjustable, voltmeter

display, accuracy ±0.5%FC±2d

0-250V adjustable, with voltage input module, voltage touch screen display 0-250V adjustable, with communication module, voltage touch screen display
Temperature acquisition and recording External temperature inspection instrument, user-provided External temperature inspection instrument, user-provided Built-in temperature input module, touch screen display, can form temperature-time curve, 4 channels
Power-on time 0-99h59min59s, presettable 0-99h59min59s, presettable 0-99h59min59s, presettable
Power-off time 0-99h59min59s, presettable 0-99h59min59s, presettable 0-99h59min59s, presettable
Number of on-off cycles 0-9999 times, presettable 0-9999 times, presettable 0-9999 times, presettable
 

Voltage adjustment method: adjust the voltage adjustment knob on the left, and the voltmeter will display the voltage value in real time.

Current adjustment method: first select the current range, then use the fine-tuning knob on the right below to adjust it, with a resolution of 0.1A. If 14A is required, you can select 1+3+4+6=14A, and then use the fine-tuning knob to adjust it at 14.0A

As shown below:

 

 

 

 

 