IEC 60884-1 2022 7 In One Modular Integrated Information Safety Analyzer
Products Description
IEC 60884-1: 2022 7 In One Modular Integrated Information Safety Analyzer
Product Information For Modular Integrated Information Safety Analyzer:
This 7 in one electrical safety tester Conforms to IEC 60884-1:2022 clause 11, 17, IEC 60669-1:2017 clause 11 and Clause 16, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 13, Clause 16, Clause 27 and etc. It integrates 7 functions of AC withstand voltage, DC withstand voltage, insulation, grounding, leakage, power, low-voltage start testing.
Features For Modular Integrated Information Safety Analyzer:
Global new modular information and safety regulation integrated analyzer, safety regulation function modular, realize information interconnection, with data acquisition, storage, analysis,
Transmission and other functions, is the best solution of the Internet factory detection.
■ 12-inch full-color touch screen, built-in touch keyboard, fast input;
■ Independently develop test system software to fully meet the requirements of intelligent testing;
■ Local storage of test data, which can be connected with MES and other information management systems;
■ Main item accuracy 1%, power test accuracy 0.2%;
■ Diversified communication modes: WIFI, network port, USB, RS232, RS485, CAN
■ Modular modular: each function module card design, multi-function selection, modular function customization, the establishment of sales service innovation system.
■ Parallel test parallel test: withstand voltage insulation and grounding can be tested at the same time, greatly shorten the overall test time, improve the test efficiency.
■ Fault self-diagnosis fault self-diagnosis: display the cause of equipment failure, with remote upgrade and modular design, to achieve a quick solution to equipment problems.
■ Remote Upgrade Remote upgrade: Remotely upgrade the latest version of the software to solve problems encountered in the use of the software and update the customization requirements.
■ Rapid discharge rapid discharge: rapid discharge patented technology, to achieve the measured object within 50ms discharge.
■ Anti-high voltage anti-high voltage GFI: : real-time monitoring loop, self-dynamic measurement of the measured object state, if there are personnel contact high voltage loop, automatically disconnect high voltage output, eliminate
Electric shock injury to ensure personnel safety
■WiFi function: it can connect to wireless network and mobile hotspot, realize network information transmission, remote diagnosis, remote upgrade and other networking functions.
■ Built-in power supply built-in power supply: frequency conversion power supply built-in, can real-time output voltage and frequency testing required, built-in power within 6KVA, more power
Can be customized.
■ Arc detection Arc detection: by detecting the abnormal current circuit of the tested object, screen out the exposed short-circuit defective products,
Bar code scanning: bar code start test, bar code test group and other functions, bar code and test data interconnection, easy data management and analysis.
■ Data management data management: real-time display of statistical data in the form of charts, conducive to data analysis and management, compatible with databases, and MES and other information systems docking.
1.000MΩ~999.9MΩ
Output 200-500V
1.000MΩ~999.9MΩ
Output 501-2500V
1.00GΩ~10.00GΩ
Output 501-2500V
10.00GΩ~50.00GΩ
Output 1000-2500V
0.1 the Rm Ω
R=(6400/ set current value)m ω
Test Probe Setup
GB12113/IEC60990,GB4706.1/IEC60335-1
GB7000.1/IEC60598-1,GB4943.1/IEC60950-1
GB4793.1/IEC61010-1,GB8898.1/IEC60065
UL544P
GB12113/IEC60990
GB7000.1/IEC60598-1
GB4943.1/IEC60950-1
GB4793.1/IEC61010-1
Test power supply
0.0V~300.0V AC
0.1V ;
45Hz~65Hz
15Hz≤f≤
100kHz
100kHz<f≤
1000kHz
Model
Test Project
Function
Accuracy
ACW
DCW
IR
GB
LC
PWR
STR
O/S
Variable frequency power supply
Transformer
1%
SN6872F
√
√
√
√
√
√
√
√
√
AC Withstand Voltage (ACW)
Rated output
5KV/100mA, short-circuit current>200mA
The output voltage range
100 ~ 5000V
Output voltage accuracy
±(1%× set value +2 words)
Voltage resolution
1V
Output frequency
50/60Hz
Frequency accuracy
±0.1Hz
Output adjustment
±(1%× set value +2 words)
Current upper limit
0.00 to 100.00mA
The current lower limit
0.000 to 9.999mA
Current measurement range
0.00 ~ 100.0mA
The current measurement resolution
0.001/0.01mA
Current measurement accuracy
±(1%× reading value +5 words)
Slow rise time
0-999.9s
Slow down time
0.1-999.9s
Test time
0,0.3-999.9s
Time resolution
0.1s
Time accuracy
±(0.2% x set value +1 word)
Arc detection
0-9
Current compensation range
0.000-20.00mA
DC Withstand Voltage (DCW)
Rated output
6KV/10mA
The output voltage range
200~6000V
Output voltage accuracy
±(1%× set value +2 words)
The output ripple
<2%
Current upper limit
0.00 to 10.00mA
The current lower limit
0.000 to 9.999mA
Current measurement range
0.00 ~ 10.0mA
The current measurement resolution
0.001/0.01mA
Current measurement accuracy
±(1%× reading value +5 words)
Slow rise time
0-999.9s
Slow down time
0.1-999.9s
Test time
0,0.3-999.9s
Time resolution
0.1s
Time accuracy
±(0.2% x set value +1 word)
Arc detection
0-9
Current compensation range
0.000-5.000mA
Discharge time
100ms
Insulation Resistance (IR)
Rated output
2500V/50GΩ
The output voltage range
200~2500V
Voltage resolution
1V
Output voltage accuracy
±(1%× set value +2 words)
Ripple coefficient
≤2%
Resistance measuring range
0.00 to 10.00mA
Resolution of resistance measurement
0.000 to 9.999mA
Accuracy of measurement
±(7%× reading value +3 words)
±(5%× reading value +3 words)
±(7%× reading value +3 words)
±(15%× reading value +3 words)
Slow rise time
0-999.9s
Slow down time
0.1-999.9s
Test time
0,0.3-999.9s
Time resolution
0.1s
Time accuracy
±(0.2% x set value +1 word)
Discharge time
<100ms
Grounding Resistance (GR)
Rated output
32A/600mΩ
The output voltage range
1.00~32.00A
Voltage resolution
0.01A
Output voltage accuracy
±(1%× set value +3words)
Current fluctuations
≤0.4% x Set value/min
The output voltage
3.00-8.00V AC
The resolution of the
0.1V
The output frequency
50Hz/60Hz
Frequency accuracy
±0.1Hz
Upper/lower resistance setting
0.1-600mΩ
Resistance range
0.1-600mΩ
1.00~10.00A
10.10~64.00A
Resolution of resistance measurement
0.1/1mΩ
Accuracy of resistance measurement
±(1%× reading value +3 words)
Voltage measuring range
0.00-6.40V AC
Voltage measurement resolution
0.01V
Accuracy of voltage measurement
±(1%× reading value +3 words)
Resistance compensation
0-100mΩ
The test of time
0,0.3-999.9s
Temporal resolution
0.1s
Time accuracy
±(0.2%× reading value +3 words)
Touch current/leakage current
Ground contact current: G-L, G-N, AUTO (G-L, G-N)
Contact current to surface: PH-L, PH-PL
7 kinds of human body simulation circuits (MD) are standard (optional customized human body network)
MD A.
MD B.
UL1563
MD C.
GB9706.1/IEC60601-1
MD D.
MD E.
UL544NP/UL484/UL923/ UL1029/UL471/UL867/UL697
MD F.
MD G.
Polarity Switching: On, Off, Auto
Grounded and Un-grounded Conversion: On, Off
The transition between the normal connection state and the non-connection state of the neutral line of the test power supply: ON, OFF
Test voltage output
Single-phase, requires an external isolation transformer or variable frequency power supply; provides the voltage and frequency required for the test.
Test voltage upper limit setting
0.0V~300.0V AC
Test voltage lower limit setting
Test voltage resolution
Test voltage measurement range
0.0V~300.0V,45Hz~65Hz
Test voltage resolution
0.1V,45Hz~65Hz
Test voltage measurement accuracy
20.0V~300.0V: ±(2%×reading value+3 digits)
load current
20A
Overcurrent Protection
RMS current and response time: 25A<3s
Peak current and response time: 70A<10ms
Touch current measurement upper limit (effective value)
0.0mA~20.000mA
Touch current measurement lower limit (RMS)
0.0mA~20.000mA
Touch current measurement resolution (RMS)
0.001mA
Touch current measurement judgment error (RMS)
AC
±(1%×reading value+3 digits)
±(1%×reading value+3 digits)
±(2%×reading value+3 digits)
Touch current compensation range
0.000~1.000mA; automatic measurement; can be turned on or off
testing time
0; (1 ~999.9); 0 is infinite
Test time resolution
0.1s
test accuracy
±( 1% × set value + 1 word)
test method
AUTO (G-L, G-N); time for 1 and a half times each
Load Power
Power upper/lower limit settings
0.0~6000W
Power measurement range
0.0-999.9W,1000-6000W
Power measurement resolution
0.1W,1W
Power Measurement Accuracy
PF>0.9
±(0.1%×reading value+0.1%×range)
PF≤0.9
±(0.4%×reading value+0.1%×range)
Voltage measurement range
0.0-300.0V
Voltage measurement resolution
0.1V
Voltage measurement accuracy
±(0.1%×reading value+0.1%×range)
testing time
0,0.3~999.9s
Time resolution
0.1s
time accuracy
±(0.2%×setting value+1 word)
Low Voltage Start
Current upper/lower limit setting
0.00-20.00A
Current measurement range
0.000-9.999A ,10.00-20.00A
Current measurement resolution
0.001A/0.01A
Current measurement accuracy
±(0.1%×reading value+0.1%×range)
Voltage measurement range
0.0-300.0V
Voltage measurement resolution
0.1V
Voltage measurement accuracy
±(0.1%×reading value+0.1%×range)
testing time
0,0.3~999.9s
Time resolution
0.1s
time accuracy
±(0.2%×setting value+1 word)
Configuration
Communication Interface
WIFI, network port, USB, RS232 (optional RS485, CAN)
Dimensions (W×H×D), mm
550*1360 (including casters without alarm light) *600
Accessories (standard)
Test box, test clamp, foot switch, alarm light, instruction manual