Products

1 Or 3 Stations Switch Life Tester IEC 60884-1 Figure 27 And 42 Power Cables Low Temperature Impact Test Apparatus
Products Description
IEC 60884-1 Figure 27 and 42 Low Temperature Impact Test Apparatus
Product information:
The low temperature impact test apparatus meets the requirements of IEC 60884-1 2013 clause 24.4, 30.4, figure 27 and 42, IEC60811-1-4, VDE0620 and so on. This device is used to check the impact resistance at low temperature of electrical accessories, as well as wires and cables.
Equipment characteristics:
This device should be used with low temperature chamber, the device should be placed on the sponge rubber pad of about 40mm thick, and should be put in the low temperature chamber before and during the test.
Technical parameters:
IEC60884-1 24.4 Figure 27
IEC60884-1 30.4 Figure 42
Table1 For power cables for fixed installation, the mass of the hammer for testing the samples shall be as given in the following table:
Table 2 For flexible cables and cords and telecommunication cables, the mass of the hammer for testing the sample shall be as follows:
Model
SN2127
SN2127A
Station
Single station
Three stations
Weight of the impact hammer (g)
1000±2 and 100±1
100, 200, 300, 400, 500, 600, 750, 1000, 1250, 1500(See table 1 and 2)
Height of the impact (mm)
100
100
Steel intermediate piece
Φ20, bottom end rounded R300, 100g
Φ20, bottom end rounded R300, 100g
Applied Standard
IEC60811-1-4
Operation
Manual, mechanical release
Manual, mechanical release
Overall diameter (mm)
Mass of hammer (g)
Above
Up to and including
-
4.0
100
4.0
6.0
200
6.0
9.0
300
9.0
12.5
400
12.5
20.0
500
20.0
30.0
750
30.0
50.0
1000
50.0
75.0
1250
75.0
-
1500
Overall diameter (mm)
Mass of hammer (g)
Above
Up to and including
For flat cords
100
-
6.0
100
6.0
10.0
200
10.0
15.0
300
15.0
25.0
400
25.0
35.0
500
35.0
-
600