IEC 60320-1 Figure 19 Coupler Lateral Pulling Test Apparatus 100N

MOQ:1
Price:Customized
StandardPackaging:CartonBox
DeliveryPeriod:20days
PaymentMethod:L/C,T/T,WesternUnion,MoneyGram
SupplyCapacity:20SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP2104

Applied Standard:IEC60320-1

Applied Clause:Clause 23.3

Standard Figure:Figure 19

Force Range:0-100N

Cable Bending Height:40±2 Mm

Pulling Method:Manual Operation

Minimum Order Quantity:1

Price:Customized

Packaging Details:Carton Box

Delivery Time:20 days

Payment Terms:L/C, T/T, Western Union, MoneyGram

Supply Ability:20 Sets Per Month

Highlight:100N Coupler Lateral Pulling Test Apparatus, IEC 60320-1 Lateral Pulling Test Apparatus


Product Description

 

IEC 60320-1 Figure 19 Coupler Lateral Pulling Test Apparatus

 

Equipment overview:

 

Th coupler lateral pulling test apparatus is manfactured according to the IEC60320-1 clause 23.3 and figure 19.

It is used to test the connector being pulled out of the appliance socket under lateral stress, so as to assess the mechanical strength of the coupler.

The connector with a rating exceeding 0,2 A is inserted into an appliance inlet of a type corresponding with the connector to be tested and complying with the relevant standard sheet. The appliance inlet is mounted in an appropriate test apparatus, an example of which is shown in IEC 60320-1 figure 19, with the pins pointing upwards. The dimension 40 mm ± 2 mm shall be complied with. A lateral pull, as specified in IEC 60320-1 table 7, is applied to the cord first in a direction perpendicular to the plane containing the axes of the current-carrying pins, and is immediately released. This sequence of operation is made 50 times in one direction and then 50 times in the opposite direction.

 

Technical Characteristics:

 

Test station Single station
Flexible cable bending height 40±2 mm,adjustable
Pull force range 0-100N
Pulling method 50 times in one direction and then 50 times in the opposite direction
Cable selection and corresponding pull value table
Appliance input socket Optional gauge according to requirements
 
 

 

 

Tags: