Products
IEC 60320-1 Coupler Lateral Pulling Test Apparatus To Pull Test For Testing Ratings Over 0.2 A
Products Description
IEC 60320-1 Coupler Lateral Pulling Test Apparatus To Pull Test For Testing Ratings Over 0.2 A
Equipment overview:
Th coupler lateral pulling test apparatus is manfactured according to the IEC60320-1 clause 23.3 and figure 19.
It is used to test the connector being pulled out of the appliance socket under lateral stress, so as to assess the mechanical strength of the coupler.
Test principle:
Plug a connector rated over 0.2 A into an appliance inlet that corresponds to the type of connector to be tested and complies with the relevant standard table. Appliance input sockets are installed in suitable test equipment, an example is shown in IEC 60320-1 Figure 19 with pins facing up. Should conform to the dimensions of 40 mm ± 2 mm. The lateral pull as specified in IEC 60320-1 Table 7 is first applied to the cord in a direction perpendicular to the plane containing the current-carrying pin axis and then released immediately. This sequence of operations is performed 50 times in one direction, then 50 times in the opposite direction.
Structure:
The connector test should be equipped with an appliance inlet of a type corresponding with the connector to be tested and complying with the relevant standard sheet.
Technical parameters:
Test station
Single station
Flexible cable bending height
40±2 mm,adjustable
Working temperature
5-35℃
Humidity
30%-90%
Pull force range
0-100N
Pulling method
50 times in one direction and then 50 times in the opposite direction
Cable selection and corresponding pull value table
Appliance input socket
Optional gauge according to requirements