IEC 60598-2-5 Outdoors Road Lamp Wind Force Resistance Test Device

MOQ:1
Price:Customized
StandardPackaging:Plywood
DeliveryPeriod:1Month
PaymentMethod:T/T
SupplyCapacity:15SetsperMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP9929

Control Method:Automatic Lifting

Sandbag Weight:100kg/Bag

Test Net Size:Diameter Of 1mm

Test Net Naterial:Polyester Fiber

Net Load Capacity:5~500 (KG)

Load Weights Type:Steel Load Set

Equipment Bracket:SUS304 Stainless Steel

Warranty Term:Free Warranty

Minimum Order Quantity:1

Price:Customized

Packaging Details:Plywood

Delivery Time:1 Month

Payment Terms:T/T

Supply Ability:15 Sets per Month

Highlight:IEC60598-2-5 Wind Force Test Device, Road Lamp Wind Force Test Device


Product Description

 

IEC 60598-2-5 Road Lamp Wind Force Test Device For Wind Resistance Test

 

Applied Standards For Road Lamp Wind Force Test Device:

 

This machine meets the standards of IEC60598-2-3:2011 clause 3.6.3.1, figure 1 IEC60598-2-5 clause 5.6.5.

 

Application For Road Lamp Wind Force Test Device:

 

It used to detect the static load test of wind resistance for street lamps outdoors.

 

Technical parameters For Road Lamp Wind Force Test Device:

 

Wind-force simulation sandbag 100kg/Bag, built-in steel ball (adjustable with various weights), two bags (small sandbags according to the test, 20 small bags with various specifications).
Control method automatic lifting console operation
Test net diameter of 1mm;load weight : 5~500 (KG);material: Polyester fiber; Convenient hook
Load weights Steel load set, chrome plated surface
Equipment bracket SUS304 stainless steel, can bear 300KG load, equipped with a variety of different street lights, tunnel light fixtures and street lamp holders, can be replaced.
 

Test principle For Road Lamp Wind Force Test Device:

 

The working principle is to use a small sandbag to spread evenly on the road lamp under test, or use a net to cover the lamp, and then test the load on the net. This device is suitable for road lampshade wind-force test, equipped with sandbags, test nets, test weights, installation of test bracket, and etc.

 

Test According To Standard:

 

1. IEC60598-2-3:2011 clause 3.6.3.1 test

 

Calculate the load applied to the lamp according to the formula.

 

 

Set test time 10min.

Press the start button to start the measurement, the disc on the right falls off the load and starts timing, and when the time is up, the disc rises to lift the load.

After the test is completed, there should be no visible damage that compromises safety, the permanent deformation of the attachment should not exceed a slope of 2 cm/m, and there should be no rotation around the attachment.

 

2. IEC60598-2-5 clause 5.6.5 test

 

For floodlights used above ground outdoors, a constant, evenly distributed load was applied to the floodlights for 10 minutes using sandbags, which provided a floodlight area of 2.4KN per square meter.

Set test time 10min.

Press the start button to start the measurement, the disc on the right falls off the load and starts timing, and when the time is up, the disc rises to lift the load.

Place the floodlight on a vertical plane, rotate 180° around the attachment point, and repeat the test.

During the test, there shall be no failure or movement in the vicinity of the connection point, and no permanent deformation of more than 1° after any part of the test.

 

 

 