5J Striking Elements Pendulum Impact Test Apparatus IEC 60598-1

MOQ:1
Price:Customized
StandardPackaging:Plywood
DeliveryPeriod:10Days
PaymentMethod:L/C,,T/T,WesternUnion,MoneyGram
SupplyCapacity:100setspermonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP2122B

Applied Standards:IEC 60598-1

Appled Specimen:Luminaries

Striking Element:5J

Equivalent Mass Kg:1.7kg

Striking Element Material:Steel

Pendulum Rod Length:1000 Mm

Minimum Order Quantity:1

Price:Customized

Packaging Details:Plywood

Delivery Time:10 Days

Payment Terms:L/C, , T/T, Western Union, MoneyGram

Supply Ability:100 sets per month

Highlight:IEC 60598-1 Pendulum Impact Test Apparatus, 5J Pendulum Impact Test Apparatus


Product Description

 

IEC 60598-1 5J Striking Elements Pendulum Impact Test Apparatus

 

Equipment Overview

This test apparatus is used for the impact resistance test of household and similar electronic and electrical products and their accessories such as plugs and sockets and wall mounted mounting boxes, screw glands, covers, switches, lamps, etc., to assess the safety performance and mechanical strength level of the products.

It is designed and manufactured according to IEC60068-2-75:2014, IEC62262:2002 and it is required by IEC60598-1:2017, IEC60884-1:2013, IEC60669-1, etc.

 

The high-energy pendulum impact test apparatus adopts a trolley structure, can move forward, backward, left and right, the impact height is adjustable through the screw guide, the impact angle is adjustable from 0 to 90°. The striking element is free released at a certain height through a 1 m pendulum rod, impact the specimen at the lowest point in the vertical direction, after the conversion of gravitational potential energy to kinetic energy, to achieve the purpose of impact test on the sample.

 

2 Technical parameters

Striking Elements (Energy/J) 5J
Equivalent Mass kg 1.7kg, please refer to following table 1
Striking Elements Material Steel
Pendulum rod Length 1000 mm, outer diameter 15.9 mm, wall thickness 1.5 mm steel pipe
Impact Point Up and down adjustable, stroke: 200-1200mm, the height can be customizable
Height of Fall 0-500mm, scale display
Striking Elements Fix and Release Method Fixed by mechanical latch, released manually
 

How to define the required impact height?

According to the relative test requirements to select impact energy and the following table, select the corresponding fall height. If the 5J energy test of IK08 is required, the fall height is 300mm.

 

IK Code IK06 IK07 IK08 IK09 IK10 -
Energy / J 1 2 5 10 20 50
Equivalent mass / kg(±2%) 0.25 0.5 1.7 5 5 10
Height of fall (±1%/mm) 400 400 300 200 400 500

 

 

 

Tags:

Related Products