Products
IEC 60598-1 Article 4.14.3 Power Cord Flexibility Test Equipment Bending Resistance Test
Products Description
IEC 60598-1 Article 4.14.3 Power Cord Flexibility Test Equipment Bending Resistance Test
Product Information:
Standard: Clause 25.14 of IEC 60335-1 Household and similar electrical appliances – Safety – Part 1: General requirements, IEC 60598-1 Article 4.14.3.
Application: It is used to test the bending resistance of the power cord of household appliances when it enters the appliance, and to verify its reliability. The purpose of verifying that the luminaire regulating device does not stress, pinch, damage or twist the cord or cable more than 360° along the longitudinal axis during normal operation is to verify its interference with the cord or cable.
Test sample: Household appliances with power supply cords (such as electric irons) or household appliances with relative motion that need to be moved during work; hand-held electric tools; bracket or extension tube
Technical Parameters:
Mechanical clamping, adjustable clamping point position, two clamping methods
Method 1 (IEC60335-1 Section 25.14):
Method 2 (IEC60335-1 Article 23.3 and IEC60598-1 Article 4.14.3):
Common Faults and Treatments:
1
2
5
Press down “Start” button, but the manipulators do not work.
Input Power
Single phase AC220V, 60Hz
Control Method
PLC control, touch screen operation
Station
One
Drive Mode
Servo motor drive
Sample clamping method
Flexing Angle
0-360°, preset on the touch screen
Choice of bending direction
Flexing Speed
0-60 cycles/min, can be preset
Test Cycles
0-999999, can be preset
Loading Weight
5N,10N,20N
Loading Voltage
0-250V, can be adjusted
Sample judgment
Judge the conduction by current
No.
Fault
Reason
Treatment
Turn on the “Power” switch, but the indicator light not turn on
The external power supply is not connected
Please connect to the external power supply
The fuse is broken
Find out the reason and change the fuse.
The indicator light damaged
Replace the light
Turn on the “Power” switch, Touchscreen not work
The internal DC24V power supply is in problem
Replace the DC24V power supply
Touchscreen damaged
Replace the touchscreen
3
Touchscreen no response
Connection to PLC loose
Reconnect
Touchscreen damaged
Replace the touchscreen
4
Load power no power supply
Load socket damaged
Replace the socket
The fuse is broken
Change the fuse
The display value and preset value of test times are the same
Press “Count Cleared” button
The E-STOP button is not reset
Release E-STOP button
There is foreign object in the machine, the machinery is stuck
Remove the foreign object
It is not under auto test mode
Press “Start” button
Connection to motor loosen
Reconnect
Not in starting position
Homing
6
Noise
Swivel speed low or too high
Reset the speed
Connection to motor loosen
Reconnect