Products
IEC 60529 IPX3 To IPX6 Spray Nozzle Hose Nozzles Testing Equipment
Products Description
IEC 60529 IPX3 to IPX6 Spray Nozzle Hose Nozzles Testing Equipment
System overview:
The test system is used to verify the protective performance of the enclosure for electronic and electrical products, automobiles, motorcycle parts, household appliances, seals and lamps under water jets at degree IPX3, IPX4, IPX5 and IPX6.
This IPX3~IPX6 spray nozzle and hose nizzle test system ensures that the water spray speed reaches the standard required value by controlling the water supply flow, the enclosure is sprayed from all practicable directions with a stream of water from the standard test nozzles as shown in IEC 60529:2013 figure 5 and 6.
It is composed of nozzles holder, turntable, intelligent water supply and control system, one IPX3/4 spray nozzle, one IPX5 hose nozzle and one IPX6 hose nozzle.
The intelligent water supply and control system consists of a water supply tank, a water supply system, and a control system. The test water supply flow is controlled by PLC, frequency converter, and turbine flow sensor. The test flow rates according to the standard requirements have been default in the control system, as long as the operator selects the waterproof test level on the touch screen, the test can be performed. And the test flow rates can also be set by operator.
Technical parameters:
Brand: South, model no.: CHL8-50, 380VAC, 50Hz, 2.2kw
Protection class: IP55 Insulation class: F
IPX3/4 spray nozzle
Item
Specifications
Power supply for this equipment
Three phase AC 380V, 50Hz, 4KW
Power supply for sample
AC220V, 16A
LWGYD-4 flow rate Sensors
Flow range: 0.667-4.167 L/min, pulse output
Large water pump
IP code test range
IPX5 hose nozzle test, IPX6 hose nozzle test, IPX3/4 spray nozzle test
Number of spray holes
121 pieces, hole diameter: φ0.5mm
Test flow
10±0.5 L/min
Test time
Set according to the test standard (range 1-9999 seconds), the unit is: second
Test pressure
50-150kPa
IPX5
Nozzle opening diameter
6.3mm
Test flow
12.5±0.625L/min
Test time
Set according to the test standard (range 1-9999 seconds), the unit is: second
Test pressure
Adjust IPX5 about 30kpa according to the specified water flow
Test distance
The distance from the nozzle to the center surface of the turntable, standard requires 2.5-3m
IPX6
Nozzle opening diameter
12.5mm
Test flow
100±5L/min
Test time
Set according to the test standard (range 1-9999 seconds), the unit is: second
Test pressure
Adjust IPX6 about 100kpa according to the specified water flow
Test distance
The distance from the nozzle to the center surface of the turntable, standard requires 2.5-3m
Turntable
1-5r/ min, can be set
Control
PLC & 7” touch screen