50W 500W Flammability Test Chamber Horizontal / Vertical Flame UL94 Fire Hazard Test
Products Description
IEC 60695-11-10 / 20 50W 500W Horizontal And Vertical Flame Test Apparatus PLC Control Fire Hazard Testing Chamber
Overview:
This horizontal and vertical flame test chamber simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. It is mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is not less than 250kg/m³ according to ISO845 test method.
Standards:
UL94
IEC60695-11-3
IEC60695-11-4
IEC60695-11-10
IEC60695-11-20
Technical Parameters:
Ф5.5mm,
1.76 g±0.01 g
(before drilling)
Ф9mm,
10g±0.05 g
(before drilling)
15 °C to 35 °C temperature,
45 % to 75 % relative humidity
This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, chamber body are made full of stainless steel, large observation window, imported thermocouple of high precision, PLC control and touch screen display, also equiped with remote controller.
KingPo offers kinds of testing equipment based on the standard requirements of IEC, BS, VDE, UL, GB, ISO and etc., and customize testing systems or devices based on clients' specific requirements, also KingPo can offer proposals for building an entire laboratory. We have our own senior professional technical team and cooperated with universities and research institutions, together with our strength manufacturing ability, we can offer clients fast reponses and one-stop service.
Flame power
50W
500W
Conforming to standards
UL94, IEC60695-11-4, IEC60695-11-10
UL94, IEC60695-11-3, IEC60695-11-20
Timing
0~9999, resolution:0.1s, can be set and displayed on touch sceen
0~9999, resolution:0.1s, can be set and displayed on touch sceen
Combustion angle
0°, 20°, 45°
0°, 20°, 45°
Gas pressure
0.1 MPa
0.1 MPa
Height of flame
Total height 20±2mm
Inner flame 40±2mm total height 125
Distance for temperature measurement
10±1mm
55±1mm
Standard for blast burner
IEC60698-11-4, UL94
IEC60695-11-3, UL94
Temperature testing
Max. 1100℃, thermocouple: type K
Max. 1100℃, thermocouple: type K
Gas flow rate
105 ml/min±5 ml/min
965 ml/min±30 ml/min
Water column height
<10mm
125mm±5mm
Temperature rise time
From 100℃±5℃ to 700℃±3℃ is 44s±2s
From 100℃±5℃ to 700℃±3℃ is 54s±2s
Accuracy of flow rate
1%
1%
Weight of copper block
Type of gas
Methane or coal gas
Methane or coal gas
Volume of chamber
0.75m³, black inner painted
Control
Mitsubishi PLC
Display
7" Weiview Touch Screen
Using environment