IEC 61000-3-2 EMC Test Equipment Harmonic Current / Voltage Fluctuations And Flicker EMI Test

MOQ:1
Price:Customized
StandardPackaging:Plywood
DeliveryPeriod:60Days
PaymentMethod:L/C,,T/T,WesternUnion,MoneyGram
SupplyCapacity:1setpermonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP669

Test Samples:Electronic Products, Lighting

Test Environmen:General Laboratory

Power Supply:220V ± 10%, 50 / 60Hz

Applied Standard:IEC 61000-3-2, IEC 61000-3-3

Minimum Order Quantity:1

Price:Customized

Packaging Details:Plywood

Delivery Time:60 Days

Payment Terms:L/C, , T/T, Western Union, MoneyGram

Supply Ability:1 set per month

Highlight:emc test systems, electromagnetic testing services


Product Description

IEC 61000-3-2 Harmonic Current, Voltage Fluctuations and Flicker EMI Test System

 

Standards & Clauses:

 

IEC 61000-3-2 / GB 17625.1: Harmonic Current Limit Issued by Low-Voltage Electrical and Electronic Equipment (Equipment Input Current ≤16A per Phase)
IEC 61000-3-3 / GB 17625.2: Limits of voltage fluctuations and flicker in low-voltage power supply systems for equipment rated up to 16A

 

Samples and Restrictions:

 

Electronic products, lighting equipment

 

Application:

 

Harmonic current testing primarily measures the harmonics injected into the grid while the EUT is operating. Voltage fluctuations and flicker mainly measure the voltage changes in grid caused by EUT.

 

Test Principle:

 

Due to extensive use of switching power supplies in electronic products, while improving power efficiency, a large amount of harmonic current is injected into the power grid due to non-linear power conversion, which not only interferes with other devices in the same power grid but also causes the neutral Current overload, affecting transmission capacity. In addition, the phase control of the power supply can also cause changes in the rms current of the power grid, causing the rms voltage on the load side to fluctuate, causing the lights of the lighting to flicker.

 

Structure:

 

Main test equipment: pure power, harmonic scintillation analyzer, EMC test software
Test environment: general laboratory

 

Use Environment​:

 

Power supply: 220V ± 10%, 50 / 60Hz

Ambient temperature: 5 °C ~ +40 °C, there should be no high concentration of dust, corrosive gas, flammable and explosive objects

 

Technical Parameters:

 

Main Test Equipment Pure power source, harmonic scintillation analyzer, EMC test software, etc.
Test Environment General laboratory
Schematic Diagram
 

Tags:

Related Products