High Voltage Insulation Flash Tester

MOQ:1
Price:Negotiable
StandardPackaging:Plywood
DeliveryPeriod:30Days
PaymentMethod:T/T,L/C,WesternUnion,MoneyGram
SupplyCapacity:10SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:BF9636H

Output Voltage Setting Range:AC 200~5000V

Output Voltage Accuracy:±(1.5%×setting+5digits)

Breakdown Current Measurement Range:0.10~100.0mA

Breakdown Current Measurement Accuracy:±(1.5%×setting+5digits)

Test Time Range:1~300s

Test Time Resolution:1s/step

Minimum Order Quantity:1

Price:Negotiable

Packaging Details:Plywood

Delivery Time:30 Days

Payment Terms:T/T, L/C, Western Union, MoneyGram

Supply Ability:10 Sets Per Month

Highlight:High Voltage Insulation Flash Tester, 5000V High Voltage Insulation Flash Tester


Product Description

 

High Voltage Insulation Flash Tester

 

Product overview:

 

■Meet the test requirements of general electrical safety standards such as IEC 60884-1:2013 clause 17, etc
■ Up to 100 groups of test condition memory, model of each group can be set, easy to find, test data can be saved via USB(optional)
■ Voltage ramp-up and ramp-down functions to meet the requirements of new industry standards;
■ Breakdown current upper and lower limit preset, intelligent judgment;
■ Digital closed-loop feedback control mode, automatic voltage regulation mode, automatic correction of output voltage/current, and not affected by the external power grid, ensuring the accuracy of the test

■ High-definition LCD display and simple panel operation

 

Technical parameter:

 

Model BF9636H
Test Contents AC and DC withstand voltage, insulation resistance
Data storage method USB (optional)
External interface Alarm LAMP, PLC, RS-232
AC withstand voltage
Output voltage setting range / accuracy

AC 200~5000V

±(1.5%×setting+5digits)

Breakdown current measurement range / accuracy

0.10~100.0mA

±(1.5%×setting+5digits)

Breakdown current preset alarm range

Upper limit :0.1~100.0mA;

Lower limit :0.00~5.00mA

Short-circuited current capacity ≥200mA (the device will enter into protection status when short-circuited current exceeds 200mA)
Test time range / resolution 1~300s 1s/step
DC withstand voltage
Output voltage setting range / accuracy DC 200~5000V ±(1.5%× setting +5 digits )
Breakdown current measurement range / accuracy 0.10~10.00mA ±(1.5%×display+5 digits)
Breakdown current preset alarm range Upper limit: 0.10~10.00mA; lower limit: 0.00~5.00mA
Test time range / resolution 1~300s 1s/step
Insulation resistance
Output voltage setting range / accuracy DC500/1000V ±(1.5%× reading +5 digits )
Insulation resistance measurement range / accuracy

1~2000MΩ:

≤100MΩ:± (5%×display+3 digits )

>100 MΩ:± (8%× display +8 digits)

Insulation resistance alarm setting range

 

Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ

Test time range / resolution

 

1~300s 1s/step

Equipment dimensions 435MM(W)*150MM(H)*550MM(D)
Equipment weight Approx. 30KGS
Equipment accessories Power cord*1, high voltage probe*1, test wire*1, fuse*1