Products
IEC 62368-1 Clause 5.4.2 Impulse Voltages Generator 2 Internal Resistances 12.5KV
Products Description
IEC 62368-1 Clause 5.4.2 Impulse Voltages Generator 2 Internal Resistances 12.5KV
Product information:
Standard: Conform to IEC 62368-1:2018 clause 5.4.2,5.5.8 and Annex D, circuit 1 and circuit 2 of Table D.1, Annex G.10, etc., IEC 60950-1:2013 clause 2.10.3.9, 5.2, reference 2 of table N.1, IEC 60950-1:2013 clause 6.2.2.1 and 7.4.3 reference 1 of table N.1, IEC60065:2014 clause 10.2, 13.3.4 a), and IEC 60065:2014 clause 13.3.4 b), 14.2, IEC60335-1 clause 14, and etc.
Application: It is used to detect the transient over voltage of the components and the electrical clearance and the creepage distance.
Test sample: Household appliance, Audio, video and similar electronic apparatus.
Feature: The sample breakdown will produce a spark and acoustic, instrument peak voltage than the no-load voltage is decreased substantially (close to zero), when applying the same voltage in the next test, it will also show the above phenomenon.
Technical parameters:
Impulse wavefront time: 1.2 µs ± 30 %;
Half value of after wave time: 50 µs ± 20 %
0-12500V,
Low: 300 V~ 2,500V;
High: 2,500 V~ 12,500V
Applied Standard
IEC 62368-1
Clause
5.42
DC high voltage
Max. 12.5kV
Impulse voltage wave
Instrument internal resistance
12Ω ± 10%
Internal resistance converter box
500Ω - 10% optional
Peak voltage: 300 V~ 12,500V
Impact interval time
5 ~ 99s
Impact cycles
1 ~ 9999
Polarity
positive and negative
Working power source
Rated voltage: ~ 220V±10%, 50Hz
Dimension
430mm×180mm×480mm
Weight
20 KG