IEC 60309-1 Vehicle Connector And Plug Breaking Capacity Testing Machine
Product Information For Vehicle Connector And Plug Breaking Capacity Testing Machine:
This test equipment meets the requirements of IEC 62196-1Ed.4CDV 2020 clause 22, 23.2, 23.3, fig 15, table 8 and table 9, IEC60309-1: 2012 clause 20 and clause 21, etc.
It is used to verify whether electrical accessories such as electric vehicle charging interfaces, industrial plugs, socket-outlets and couplers can withstand the mechanical, electrical and thermal stresses that occurred during normal operation without excessive wear or other harmful effects.
The servo motor drives the mechanism to make the test samples repeat insertion and withdrawal actions. An external load can be used for the breaking capacity test. The power on / off time, test speed, stroke, and angle can all be preset on the touch screen.
Technical parameters For Vehicle Connector And Plug Breaking Capacity Testing Machine:
Appliance coupler/charging interface breaking capacity test
Appliance coupler / charging interface normal operating life test
Equipment Dimension
& Weight
Structure For Vehicle Connector And Plug Breaking Capacity Testing Machine:
It adopts integral frame, driven by servo motor, precision ball screw and timing belt, with color touch screen for humanized operation and powerful digital display, and PLC for intelligent control, adopts three-axis adjustable clamp for charging interface life span test.
Test Station
Single, can be customized
Electrical Control Method
PLC intelligent integrated control, with color humanized touch screen
Drive Mode
Servo motor drive
Sample Clamping Method
Mechanical clamping, the position of clamping point can be adjustable along the 3-axis fixture
Linear Stroke
0-100mm, can be preset (the spacing between test plug and test socket≥ 50mm)
Conduction Time
0-99.9s, can be preset (electrical contact should be maintained no more than 4s, no less than 2s)
Speed of Insertion and Separation
0-0.85m/s can be preset, default (0.8±0.1) m/s
Test Cycles
0~999999 cycles, can be preset (A stroke is an insertion or a withdrawal of a plug or vehicle connector with its mating accessory. A cycle is composed of two strokes, one for insertion and one for withdrawal.)
Test Frequency
0-10 cycles/min, can be preset (3.75cycles/min=7.5 stoke/min)
Load Power
External, providing standard required voltage, current and power factor, recommended to work with the load cabinet SN224-300V80A
Test Contents
Detection Function
An open circuit alarm can be realized during testing under load, and the cycles can be recorded real in time.
Safety Protection
Ground protection, short circuit protection
Power Supply
Single phase AC220V±10%, 50/60Hz, 10A
L 1430mm * W 600mm * H1620mm, approx. 180KGS