IEC 60320-1 Coupler Lateral Pulling Test Apparatus To Pull Test For Testing Ratings Over 0.2 A

MOQ:1
Price:Customized
StandardPackaging:CartonBox
DeliveryPeriod:20days
PaymentMethod:L/C,T/T,WesternUnion,MoneyGram
SupplyCapacity:20SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP2104

Applied Standard:IEC60320-1

Applied Clause:Clause 23.3

Humidity:30%-90%

Force Range:0-100N

Cable Bending Height:40±2 Mm

Pulling Method:Manual Operation

Test Station:Single

Working Temp.:5-35℃

Minimum Order Quantity:1

Price:Customized

Packaging Details:Carton Box

Delivery Time:20 days

Payment Terms:L/C, T/T, Western Union, MoneyGram

Supply Ability:20 Sets Per Month

Highlight:Coupler Lateral Pulling Test Apparatus, IEC 60320-1 Pulling Test Apparatus


Product Description

 

IEC 60320-1 Coupler Lateral Pulling Test Apparatus To Pull Test For Testing Ratings Over 0.2 A

 

Equipment overview:

 

Th coupler lateral pulling test apparatus is manfactured according to the IEC60320-1 clause 23.3 and figure 19.

It is used to test the connector being pulled out of the appliance socket under lateral stress, so as to assess the mechanical strength of the coupler.

 

Test principle:

 

Plug a connector rated over 0.2 A into an appliance inlet that corresponds to the type of connector to be tested and complies with the relevant standard table. Appliance input sockets are installed in suitable test equipment, an example is shown in IEC 60320-1 Figure 19 with pins facing up. Should conform to the dimensions of 40 mm ± 2 mm. The lateral pull as specified in IEC 60320-1 Table 7 is first applied to the cord in a direction perpendicular to the plane containing the current-carrying pin axis and then released immediately. This sequence of operations is performed 50 times in one direction, then 50 times in the opposite direction.

 

Structure:

 

The connector test should be equipped with an appliance inlet of a type corresponding with the connector to be tested and complying with the relevant standard sheet.

 

Technical parameters:

 

Test station Single station
Flexible cable bending height 40±2 mm,adjustable
Working temperature 5-35℃
Humidity 30%-90%
Pull force range 0-100N
Pulling method 50 times in one direction and then 50 times in the opposite direction
Cable selection and corresponding pull value table
Appliance input socket Optional gauge according to requirements
 
 

Tags: