IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions

MOQ:1
Price:Negotiable
StandardPackaging:PlywoodCase
DeliveryPeriod:30Days
PaymentMethod:T/T
SupplyCapacity:15SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP2212

Capacity:5KVA

Accuracy:1.5%

Output Frequency:50/60Hz

Output Waveform:Sine Wave

Test Range:1~300s

Test Step:1s/step

Output Voltage Setting Range:AC 200~5000V

Output Voltage Accuracy:±(1.5%×setting+5words)

Minimum Order Quantity:1

Price:Negotiable

Packaging Details:Plywood Case

Delivery Time:30 Days

Payment Terms:T/T

Supply Ability:15 Sets Per Month

Highlight:5KVA Multimeter Electrical Safety Tester, IEC 60335-1 Electrical Safety Tester


Product Description

 

IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions

 

Product Information For Multimeter Electrical Safety Tester:

 

This multitester electrical safety tester Conforms to IEC 60598-1 clause 8.2.3, clause10.2.1, clause 10.2.2, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 13, Clause 16, Clause 27 and etc. It integrates 6 functions of hi-pot, insulation, grounding, leakage, power, low-voltage start testing.

 

Features For Multimeter Electrical Safety Tester:

 

■Meet CCC, IEC, EN, VDE, BS, GS, UL and other electrical safety standards

■Unlimited storage of test conditions and test results

■Data can be copied via USB

■Fast speed: ARM high-speed processor is used as the control core of the test instrument, and data processing is comprehensive and fast

■High accuracy: safety test accuracy up to 1.5%

■Ramp rise and down of voltage withstand can be set, and with upper and lower limit alarm function

■Digital closed-loop feedback control mode, fully automatic voltage regulation mode, output voltage / current is automatically corrected, and it is not affected by external power grid fluctuations to ensure the accuracy of the test

■Two judgment modes can be chosen for ground resistance test: voltage and resistance, to meet the requirements of different national / industry standards

■Built-in one human body network fora leakage current test, which can be customized to any human body network-optional function

 

Technical Parameters For Multimeter Electrical Safety Tester:

 

Model Functions Capacity Accuracy
SN2212 ACW/IR/GB/LC/PWR/STR Built-in Frequency Power Supply, 5KVA 1.5%
AC withstand voltage
Output voltage setting range AC 200~5000V
Output voltage accuracy ±(1.5%×setting+5words)
Output voltage setting step 1V
Output frequency 50/60Hz

Output waveform

Sine wave
Distortion of output waveform Less than 2% (at purely resistive load)
Output waveform adjustment rate Less than(2%* setting +5V)
Output capacity 500VA
Output voltage ramp-down time setting range 0~300s
Set step 0.1s
Breakdown current measurement range 0.10~99.99mA
Breakdown current test accuracy ±(1.5%×reading+5words)
Breakdown current preset upper limit 0.10~99.99mA
Breakdown current preset lower limit 0.00~5.00mA
Breakdown current preset step 0.01mA/step
Test time setting range 1~300s
Test time setting step 1s/step
Arc detection 1~9 Level (level 9 is the highest sensitivity)
Insulation resistance
Output voltage setting range DC 200~1000V
Output voltage accuracy ± (1.5%×reading+5 words)
Output voltage setting step 1V
Output capacity 60VA

Output voltage ramp-down time setting range

 

0~300s
Set step 0.1s
Insulation resistance measurement range / accuracy 1~2000 MΩ ≤100 MΩ:±(5%×displaying+3words) >100 MΩ:±(8%×displaying+8words)
Insulation resistance alarm setting range Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ
Test time range, resolution 1~300s 1s/step
Ground resistance
Ground current output range / accuracy AC 5.0~30.0A
Ground current accuracy ±(1.5%×setting+0.2A)
Ground resistance measurement range 10.0~600mΩ
Ground resistance measurement accuracy ±(1.5%×displaying+3mΩ)
Ground resistance alarm setting range

Upper limit: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;

lower limit:0.0~100mΩ

Ground resistance setting step 1mΩ
Test time range 1~300s
Test time step 1s/step
Leakage current
The output voltage 1.06 times rated voltage provided by the built-in variable frequency power supply
Leak type setting Dynamic leakage, static leakage, built-in one leakage current human body network, any human body network can be customized
Output voltage measurement range AC 50~280V
Output voltage frequency AC 45~65Hz
Output voltage accuracy ±(0.5%×displaying+2words)
Leakage current measurement range 0.05~20.00mA
Leakage current measurement accuracy ± (1.5%× displaying +10uA)
Leakage current setting alarm range Upper limit: 0.05 ~ 20.00mA; lower limit: 0.01 ~ 5.00mA
Leakage current setting step 0.01mA
Test time range 1~300s 1s/step
Power
Output voltage 1.0 times rated voltage, provided by built-in variable frequency power supply
Output voltage measurement range / accuracy AC 50~280V ±(0.5%×displaying+2 words)
Output current measurement range / accuracy AC 0.20~30.00A ±(0.5%× displaying +2 words )
Active power measurement range / accuracy 30~6000W ±(0.5%× displaying +5 words )
Power setting alarm range Upper limit: 3 ~ 6000W , Lower limit: 0 ~ 6000W
Test time range / resolution 1~300s 1s/step
Low voltage start
Output voltage 0.85 times rated voltage provided by the built-in variable frequency power supply
Output voltage measurement range / accuracy AC 50~280V ±(0.5%× displaying +2words)
Starting current measurement range / accuracy AC 0.20~30.00A ±(0.5%× displaying +2 words )
Current setting alarm range Upper limit:0.20~30.00A Lower limit: 0.00~25.00A
Test time range 1~300s 1s/step
Communication Interface 232 485 can Bus TCP / IP interface
External control method PLC interface, switch signal
System appearance Size:600W*1840H*600Dmm Height with pulley, alarm light
System standard accessories Power cord × 1, foot switch × 1, 30A test clamp × 1, test box × 1, power input line × 1, fuse tube × 1
 
 