IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions
Products Description
IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions
Product Information For Multimeter Electrical Safety Tester:
This multitester electrical safety tester Conforms to IEC 60598-1 clause 8.2.3, clause10.2.1, clause 10.2.2, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 13, Clause 16, Clause 27 and etc. It integrates 6 functions of hi-pot, insulation, grounding, leakage, power, low-voltage start testing.
Features For Multimeter Electrical Safety Tester:
■Meet CCC, IEC, EN, VDE, BS, GS, UL and other electrical safety standards
■Unlimited storage of test conditions and test results
■Data can be copied via USB
■Fast speed: ARM high-speed processor is used as the control core of the test instrument, and data processing is comprehensive and fast
■High accuracy: safety test accuracy up to 1.5%
■Ramp rise and down of voltage withstand can be set, and with upper and lower limit alarm function
■Digital closed-loop feedback control mode, fully automatic voltage regulation mode, output voltage / current is automatically corrected, and it is not affected by external power grid fluctuations to ensure the accuracy of the test
■Two judgment modes can be chosen for ground resistance test: voltage and resistance, to meet the requirements of different national / industry standards
■Built-in one human body network fora leakage current test, which can be customized to any human body network-optional function
Technical Parameters For Multimeter Electrical Safety Tester:
Output waveform
Output voltage ramp-down time setting range
Upper limit: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;
lower limit:0.0~100mΩ
Model
Functions
Capacity
Accuracy
SN2212
ACW/IR/GB/LC/PWR/STR
Built-in Frequency Power Supply, 5KVA
1.5%
AC withstand voltage
Output voltage setting range
AC 200~5000V
Output voltage accuracy
±(1.5%×setting+5words)
Output voltage setting step
1V
Output frequency
50/60Hz
Sine wave
Distortion of output waveform
Less than 2% (at purely resistive load)
Output waveform adjustment rate
Less than(2%* setting +5V)
Output capacity
500VA
Output voltage ramp-down time setting range
0~300s
Set step
0.1s
Breakdown current measurement range
0.10~99.99mA
Breakdown current test accuracy
±(1.5%×reading+5words)
Breakdown current preset upper limit
0.10~99.99mA
Breakdown current preset lower limit
0.00~5.00mA
Breakdown current preset step
0.01mA/step
Test time setting range
1~300s
Test time setting step
1s/step
Arc detection
1~9 Level (level 9 is the highest sensitivity)
Insulation resistance
Output voltage setting range
DC 200~1000V
Output voltage accuracy
± (1.5%×reading+5 words)
Output voltage setting step
1V
Output capacity
60VA
0~300s
Set step
0.1s
Insulation resistance measurement range / accuracy
1~2000 MΩ ≤100 MΩ:±(5%×displaying+3words) >100 MΩ:±(8%×displaying+8words)
Insulation resistance alarm setting range
Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ
Test time range, resolution
1~300s 1s/step
Ground resistance
Ground current output range / accuracy
AC 5.0~30.0A
Ground current accuracy
±(1.5%×setting+0.2A)
Ground resistance measurement range
10.0~600mΩ
Ground resistance measurement accuracy
±(1.5%×displaying+3mΩ)
Ground resistance alarm setting range
Ground resistance setting step
1mΩ
Test time range
1~300s
Test time step
1s/step
Leakage current
The output voltage
1.06 times rated voltage provided by the built-in variable frequency power supply
Leak type setting
Dynamic leakage, static leakage, built-in one leakage current human body network, any human body network can be customized
Output voltage measurement range
AC 50~280V
Output voltage frequency
AC 45~65Hz
Output voltage accuracy
±(0.5%×displaying+2words)
Leakage current measurement range
0.05~20.00mA
Leakage current measurement accuracy
± (1.5%× displaying +10uA)
Leakage current setting alarm range
Upper limit: 0.05 ~ 20.00mA; lower limit: 0.01 ~ 5.00mA
Leakage current setting step
0.01mA
Test time range
1~300s 1s/step
Power
Output voltage
1.0 times rated voltage, provided by built-in variable frequency power supply
Output voltage measurement range / accuracy
AC 50~280V ±(0.5%×displaying+2 words)
Output current measurement range / accuracy
AC 0.20~30.00A ±(0.5%× displaying +2 words )
Active power measurement range / accuracy
30~6000W ±(0.5%× displaying +5 words )
Power setting alarm range
Upper limit: 3 ~ 6000W , Lower limit: 0 ~ 6000W
Test time range / resolution
1~300s 1s/step
Low voltage start
Output voltage
0.85 times rated voltage provided by the built-in variable frequency power supply
Output voltage measurement range / accuracy
AC 50~280V ±(0.5%× displaying +2words)
Starting current measurement range / accuracy
AC 0.20~30.00A ±(0.5%× displaying +2 words )
Current setting alarm range
Upper limit:0.20~30.00A Lower limit: 0.00~25.00A
Test time range
1~300s 1s/step
Communication Interface
232 485 can Bus TCP / IP interface
External control method
PLC interface, switch signal
System appearance
Size:600W*1840H*600Dmm Height with pulley, alarm light
System standard accessories
Power cord × 1, foot switch × 1, 30A test clamp × 1, test box × 1, power input line × 1, fuse tube × 1