IEC 60335-1 Electrical Appliance Testing Equipment 12.5kV 1.2/50μS Or 7kV 10/700μS Impulse Voltages Generator

MOQ:1
Price:Customized
StandardPackaging:Plywood
DeliveryPeriod:30Days
PaymentMethod:L/C,,T/T,WesternUnion,MoneyGram
SupplyCapacity:20setspermonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP1104

Output Voltage:12.5kV (Max) Or 7kV (Max)

Front Time:1.2μs Or 10μs

Time To Half -Value:50μs Or 700μs

Output Impedance:12Ω Or 40Ω

Minimum Order Quantity:1

Price:Customized

Packaging Details:Plywood

Delivery Time:30 Days

Payment Terms:L/C, , T/T, Western Union, MoneyGram

Supply Ability:20 sets per month

Highlight:ac hipot test equipment, glow wire test equipment


Product Description

 

IEC 60335-1 12.5kV 1.2/50μs or IEC60950-1 7kV 10/700μs Impulse Voltages Generator
 
Standards & Clauses:
 
IEC60335-1:2016 “Household and similar electrical appliances-Safety-Part1:General requirements” clause 14
IEC60950-1:2013 “Information technology equipment-Safety-Part1:General requirements” clause1.5.7.2, 1.5.7.3,2.10.3.9,6.2.2.1,7.4.2,7.4.3,G5,Annexe N
IEC60065:2014 “Audio, video and similar electronic apparatus-Safety requirements” clause13.3.4,Annex J.5, Annex K
IEC 61180-1:2016 “High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements, test equipment” clause 7
 
Samples and Restrictions:
 
Household and similar appliances, information technology equipment, audio and video electronic equipment.


Application:
 
It is used to verify that the appliances shall withstand the transient over-voltages to which they may be subjected.

 
Test Principle:
 
The impulse voltage generator with a wave of 1.2/50us(10/700us is optional) is a standard lightning wave test device. The front time of the impulse voltage is 1.2us(10us), the time to half -value is 50us(700us). The impulse voltage test is a destructive test in which a breakdown occurs if the test specimen cannot withstand the applied voltage. When the sample breaks down, sparks and discharge sounds will be generated. The peak voltage of the instrument will drop significantly (close to zero) when it is no-load. When the same voltage is applied again, the above phenomenon will occur.
 
Structure:
 
Equipment size: about 470 × 260 × 500 (mm) W × D × H
Equipment weight: 30kg
 
Use Environment:
 
Power supply:AC220V±10%/50-60Hz or match client's local power supply requirements
Temperature: 15 ° C -35 ° C, relative humidity 10% -75%

 
Technical Parameters:

 

Model SN1104 SN1104-2
Open Circuit Output voltage 12.5kV (Max) ±5% 6kV (Max) ±5%
Front Time 1.2μs ±30% 10μs ±30%
Time to Half -value 50μs ±20% 700μs ±20%
Output Polarity Positive, negative, positive & negative cycling Positive, negative, positive & negative cycling
Output Impedance (optional) 12Ω±10%,500Ωis optional 40Ω±10%
Trigger Mode Automatic or manual, single trigger Automatic or manual, single trigger
Test Times 1-9999 times 1-9999 times
Interval Time 3-999s(3s of which is the charging time inherent in the device) 3-999s (3s of which is the charging time inherent in the device)

Measured Waveform
(for reference)

 

 
Note: the waveform will be shown by an external oscilloscope (oscilloscope should be prepared by user)


 
Note: the waveform will be shown by an external oscilloscope (oscilloscope should be prepared by user)

 

Tags:

Related Products