Products
IEC 60335-2-23 Power Cord Flexibility Test Equipment PLC Control With Universal Fixtures
Products Description
IEC 60335-2-23 Power Cord Flexibility Test Equipment PLC Control With Universal Fixtures
Product Information:
Standard applied: IEC60335-1 clause 23.3 and 25.14, IEC 60335-2-23 clause 23.3 and 11.101.
Test sample: Small household appliances (such as coffee pot, electric iron, toaster, luminaires and etc.), and skin or hair care appliances.
Feature: The test device adopts to PLC electrical control, 7-inch color touch screen intelligent operation system; servo motor controlling the test angle, high precision digital instrument, high performance digital frequency conversion, precise speed regulation, six number memory timer, multifunctional combined clamps, center gauge of rotation, flexing and rotation angles adjustable, 4kw output power, can also supply load current to test sample (1.25 times of test sample’s rated current). Test times (maximum of 999999 times), test speed, and test angles can be preset; it has electric current detection function. This device can meet the test requirements of most of small household electrical appliances, the applicable range is widely.
Technical Parameters:
Universal fixtures for IEC60335-1 clause 25.14 test, 1 set
Universal fixture and a positioning platform which can be raised and lowered for IEC60335-1 clause 23.3 test, 1 set
* The is a guide rail on the bottom plate for moving the lifting platform part to the right side, to avoid affect sample placement when process other tests.
Universal fixture for IEC 60335-2-23 clause 11.101, 1 set
Common Faults and Treatments:
1
2
5
Press down “Start” button, but the manipulators do not work.
Flexing or rotation angle
0-360°. Can be preset
Flexing or rotation speed
0~60 rpm, can be preset
Test times
0~999999 times, can be preset and displayed
Input Power
Single phase 220V, 60Hz
Control
PLC programmable control
Drive
Servo motor
Operation
7” Touch screen intelligent operation
Max. output power
4KW
Output voltage
0~250V
Output current
0~16A
Max. carrying capacity
30kg
Test station
1 station
Specimen fixtures
Temperature Measuring
Hand-held infrared thermometer, -50°C~380°C
Load weights
1N*1, 5N*1,10N*1
No.
Fault
Reason
Treatment
Turn on the “Power” switch, but the indicator light not turn on
The external power supply is not connected
Please connect to the external power supply
The fuse is broken
Find out the reason and change the fuse.
The indicator light damaged
Replace the light
Turn on the “Power” switch, Touchscreen not work
The internal DC24V power supply is in problem
Replace the DC24V power supply
Touchscreen damaged
Replace the touchscreen
3
Touchscreen no response
Connection to PLC loose
Reconnect
Touchscreen damaged
Replace the touchscreen
4
Load power no power supply
Load socket damaged
Replace the socket
The fuse is broken
Change the fuse
The display value and preset value of test times are the same
Press “Count Cleared” button
The E-STOP button is not reset
Release E-STOP button
There is foreign object in the machine, the machinery is stuck
Remove the foreign object
It is not under auto test mode
Press “Start” button
Connection to motor loosen
Reconnect
Not in starting position
Homing
6
Noise
Swivel speed low or too high
Reset the speed
Connection to motor loosen
Reconnect