IEC 60335-2-80 Fig. 102 Ceiling Fan Test Pin Simulating Wear On Bolt

MOQ:1
Price:Customized
StandardPackaging:CartonBox
DeliveryPeriod:5Days
PaymentMethod:L/C,T/T,WesternUnion,MoneyGram
SupplyCapacity:100SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP2210-52

Applied Standard:IEC 60335-2-80

Applied Clause:Clause 22.102.1

Applied Figure:Figure 102

Test Pin Material:Stainless Steel

Full Thickness Section With Length:At Least Equal To That Of Original Bolt

Reduced Thickness Section With Length:At Least Equal To That Of Original Bolt

Minimum Order Quantity:1

Price:Customized

Packaging Details:Carton Box

Delivery Time:5 Days

Payment Terms:L/C, T/T, Western Union, MoneyGram

Supply Ability:100 Sets Per Month

Highlight:IEC 60335-2-80 Ceiling Fan Test Pin, Figure 102 Fan Testing Pin


Product Description

 

IEC 60335-2-80 Fig. 102 Ceiling Fan Test Pin Simulating Wear On The Bolt

 

Product overview:

 

This stainless steel test pin meets the requirements of IEC60335 -2- 80 clause 22.102.1, figure 102.

It is simulated wear on the bolt of ceiling fans.

 

Technical Characteristics:

 

Applied Standards & Clauses IEC60335 -2- 80 clause 22.102.1, figure 102
Test Pin Material Stainless steel
Full Thickness Section with Length At least equal to that of original bolt
Reduced Thickness Section with Length At least equal to that of original bolt
Diameter of a Same as the original bolt that connects the down rod to the motor
Diameter of b 50% "a"
 

How to process the test with the test pin? (Extracted from IEC 60335-2-80:2015 clause 22.102.1)

 

The bolt that connects the down rod to the motor is replaced with the specially prepared test pin shown in Figure 102 that simulates wear on the bolt. The pin is fully inserted so that it connects the down rod to the motor.

 

The fan is supplied at rated voltafe and operated at maximum speed. The pin is them partially withdrawn so that the motor is connected to the down rod by that part of the pin having diameter b.

 

The supply to the ceiling fan shall be automatically disconnected and the fan shall not be capable of operation without replacing the worn bolt.

 

 

 

Tags:

Related Products