IEC 60884-1 Figure 8 Compression Resistance Performance Tester For Plug 300N Single Working Station

MOQ:1SET
Price:negotiable
StandardPackaging:plywood
DeliveryPeriod:15days
PaymentMethod:L/C,T/T
SupplyCapacity:20sets/permonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate(cost additional )

Model Number:KP2108

Standard:IEC60884 Clause 10.1, 24.5 And Figure 8

Test Sample:Plugs

Station:Single Station

Weights:300N

Operation:Manual

Test Time:1 Min

Minimum Order Quantity:1 SET

Price:negotiable

Packaging Details:plywood

Delivery Time:15 days

Payment Terms:L/C, T/T

Supply Ability:20 sets/per month

Highlight:switch endurance tester, switch life testing machine


Product Description

 

IEC 60884-1 Figure 8 Compression Resistance Performance Tester For Plug 300N Single Working Station

 

Standard: IEC 60884-1 2013 clause 10.1, 24.5 and figure 8

 

Application: This device is use for testing the compression resistance performance of plug, check whether the mechanical strength of plug comply with standard requirements.

 

Test sample: Plugs

 

Feature: This device applying compression force 300N by weights. The temperature of the pressure plate, of the base and of the specimens being 23±2℃, compress the plug in two position show as figure 8a) and 8b), each position for 1min.

 

Parameters:

 

Item Parameters
Model SN2108
Standard IEC60884 clause 10.1, 24.5 and figure 8
Weights 300N (pile up with 2 150N weights)
Station 1 station
Operation manual
Test time 1min
Material Stainless Steel
Using temperature 23±2℃
 

 

Test method:

 

The specimens are subjected to a compression test as shown in figure 8, the temperature of the pressure plate, of the base and of the specimens being (23±2) ℃ and the force applied being 300 N.

The specimens are first placed in position a), as shown in figure 8, and the force is applied for 1 min. They are then placed in position b), as shown in figure 8, and again subjected to the force for 1 min.

The specimens are removed from the test apparatus and after 15 min they shall show no damage within the meaning of this standard.

 

Notice:

 

1. Please do not damage the appliance shape (such as scratching, bending, etc.).

2. Prevented from dust and moisture environment, in order to avoid the oxidation to affect the dimensional accuracy.

 

 

 