IEC 62133 Cells 11.6 kPa High Altitude Simulation Low Pressure Vacuum PLC Control Test Chamber
Price:Customized
StandardPackaging:Plywood
DeliveryPeriod:1Month
PaymentMethod:L/C,T/T,WesternUnion,MoneyGram
SupplyCapacity:20SetsPerMonth
Products Description
IEC 62133 Cells 11.6 kPa High Altitude Simulation Low Pressure Vacuum Test Chamber
Overview:
It is for battery low pressure (high attitude) simulation testing, all the testing specimen are being tested under 11.6kPa (1.68psi).
To judge the test result on condition of no explosion, flame, smoke, electric leakage after test. And the battery protection valve should not be broken.
Standards Compliant:
It conforms to IEC62133:2017 clause 7.3.7, IEC62133:2012 clause 7.3.7, IEC60086-4 clause 6.4.1, IEC 60086-1, UN 38.3, UL 1642, IEC61960, and etc.
Structure:
- The outer chamber adopts high quality cold rolled steel plate, powder painted surface, with strong anti-rust ability.
- The working room is made of high-quality stainless-steel plate, rounded shape, smooth, and easy for cleaning.
- Between working room and outerchamber, filled with superfine glass fiber insulation material.
- Chamber door adopts double toughened glass, available for clear observation of the inside chamber.
- Rubber sealing ring between working room and glass door is Installed, to ensure high vacuum rate inside the chamber.
- Integrated type: low pressure chamber on upper side, and vacuum pump on bottom side.
Technical Parameters:
Temp. Range |
Ambient Temperature
Note: When using, the internal temperature of the laboratory must be controlled to be (20°C+5°C) to reach the temperature requirement in the test box.
|
Display Method | Touch Screen |
Control | PLC |
Pressure Unit | Kpa |
Internal Dimension | W600 X D600 X H600mm |
Internal Material | SUS 304# Stainless Steel |
External Dimension | W940 X D780 X H1620mm |
External Material | SECC steel plate, powder painted (thickness 1.5mm) |
Bottom | Installed with casters |
Observation Window | Toughened glass with explosion - proof membrane |
Timer | 0~9999(Hour, Minutes, Seconds changeable, can be preset and displayed on touch screen) |
Vacuum Rate
Safety Devices
|
1.3Kpa(standard requires 11.6Kpa, vacuum gauge indication value -89.7Kpa) |
Remarks: as the inner chamber pressure is(101.325Kpa), if wants the inner chamber pressure decreased to 11.6Kpa. Calculating according to atmosphere pressure of(101.325Kpa), need to blow out (89.7Kpa) pressure of the inside chamber, then the inner chamber can reach low pressure environment of (11.6Kpa). | |
Pressure Range | 0~100Kpa(Controllable, display) |
Pressure Fluctuation | ≤5% |
Power Source | AC 220V 60HZ |
Power | 2.0KW |
Working Principle | ![]() |
Touch Screen Monitoring
(in English)
|
|
Tags:batterydischargeanalyzerbatterytestchamberLithiumbatterytester