IEC 62368-1 Annex S Needle Flame Test Method Fire Hazard Testing Apparatus

MOQ:1
Price:Negotiable
StandardPackaging:StandardExportingPlywoodCase
DeliveryPeriod:30Days
PaymentMethod:L/C,T/T
SupplyCapacity:10SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP773

Applied Standard:IEC 62368-1

Applied Clause:Annex S

Working Voltage:AC 220V/50Hz

Control:PLC Control

Test Temperature Range:0~1000℃

Timing Device:9999X0.1S

Display:7-inch Color Touch Screen

Combustion Angle:Tilt 45° Or Vertical

Minimum Order Quantity:1

Price:Negotiable

Packaging Details:Standard Exporting Plywood Case

Delivery Time:30 Days

Payment Terms:L/C, T/T

Supply Ability:10 Sets Per Month

Highlight:IEC 62368-1 Fire Hazard Testing Apparatus, Annex S Fire Hazard Testing Apparatus, PLC Fire Hazard Testing Apparatus


Product Description

 

IEC 62368-1 Annex S Needle-flame Test Method Fire Hazard Testing Apparatus

 

Product Information:

The Needle-flame Test Method Fire Hazard Testing Apparatus is designed and manufactured according to the standard requirements of IEC 62368-1 Annex S, IEC60335-1 clause 30.2, Annex E, etc.

It consists of a Ф0.9mm needle-shaped burner that tilts with the angel of 45°and provide it with butane gas. The fire hazard of the equipment when there is flammule inside the equipment that caused due to the fault condition is assessed by whether the specimen can be ignited or the combustion time and length.

The Needle Flame Tester has PLC control and 7-inch color touch screen, it is suitable for the research, production and quality testing department of lighting equipment, low-voltage apparatus, household appliance, machine tool electric appliance, electrical machine, electric tool, electronic instrument, electrotechnical instrument, electrical connector, electrical and electronical equipment and other components. It is also suitable for insulating material, engineering plastics or other solid combustion material industry.

 

Technical parameters:

Applied standard IEC 62368-1
Applied clause Annex S
Working voltage AC 220V/50Hz
Control PLC
Display 7-inch color touch screen
Timing device 9999X0.1S
Combustor Inner boreφ0.5mm ± 0.1mm, OD ≤φ0.9mm, L ≥ 35mm, stainless steel
Combustion angle tilt 45° (testing) or vertical (when adjust the height of the flame)
Height of the flame 12±1mm adjustable (with flame height gauge)
Gas category 95% butagas (can use the bottled lighter gas)
Range of temperature test 0~1000℃
Flame warming requirement From 100°to 700°, time for standard values within 23.5S±1S
Temperature thermocouple φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple
Work shop 0.5 cube, stainless steel case, black yogin background
Testing process Test procedure automatic control, independent air draft
Volume size adjustment Flowmeter adjustment
Equipment size & weight 1100mm* 550mm* 1100mm, 120KGS
 

 

 

 

Tags: