IEC 62368-1 Clause 5.4.1.10 Vicat Softening Temperature Determination Tester

MOQ:1
Price:Negotiable
StandardPackaging:StandardExportingBoxed
DeliveryPeriod:20Days
PaymentMethod:L/C,T/T
SupplyCapacity:30SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP300FA

Applied Standard:IEC 62368-1

Applied Clause:5.4.1.10

Fuel Tank Capacity:12.5 Liters

Heating Rate:120±10℃/h (12℃±1℃/6min) , 50 ± 5℃/h(5℃±0.5℃/6min

Temperature Error:±1℃

Deformation Error:±0.01mm

Minimum Order Quantity:1

Price:Negotiable

Packaging Details:Standard Exporting Boxed

Delivery Time:20 Days

Payment Terms:L/C, T/T

Supply Ability:30 Sets Per Month

Highlight:Vicat Softening Temperature Determination Tester, IEC 62368-1 Temperature Determination Tester, Clause 5.4.1.10 Temperature Determination Tester


Product Description

 

IEC 62368-1 Clause 5.4.1.10 Vicat Softening Temperature Determination Tester

 

Product Information:

This test apparatus designed and manufactured according to the standard of IEC60065:2014 clause 7.2 and table 3, ISO75-1, ISO306.

It is mainly used for the determination of thermal deformation temperature and Vicat softening point temperature of non-metallic materials such as plastics, hard rubber, nylon, electrical insulating materials, long fiber reinforced composite materials, high-strength thermosetting extrusion materials, etc. Which is widely used in colleges and universities, scientific research units and product quality supervision and inspection units.

The instrument adopts PLC (programmable controller), touch screen display and operation, and the modular design temperature control unit, which make the performance of the instrument more stable and the operation easier and more convenient.

During the operation, operator only inputs the specimen size, the standard deflection and required weight of the test will be automatically calculated out, avoiding human calculation errors.

The test process can be completed by following the displayed prompts, with high degree of automation, low failure rate, and simple maintenance. It is an advanced instrument used for the determination of thermal deformation and vicat softening point temperature of non-metallic materials.

 

Technical Parameters:

Applied standard IEC 62368-1
Applied clause 5.4.1.10
Temperature range Room temperature -300℃
Heating rate

120±10℃/h (12℃±1℃/6min)

50 ± 5℃/h(5℃±0.5℃/6min)

Temperature error ±1℃
Deformation error ±0.01mm
Minimum resolution of temperature 0.1℃
Minimum resolution of deformation 0.001mm
Load range 0.864N-49.03N
Load error ±0.5%
Support span 64-100mm continuously adjustable
Heating power 3KW
Power supply voltage AC220V/50Hz
AC220V/50Hz Methyl silicone oil (the flash point temperature of the medium should be higher than the maximum test temperature)
Cooling method Natural cooling above 150℃, water cooling or natural cooling below 150℃
This machine has a horizontal host, and its dimensions 560×620×640
Fuel tank capacity 12.5 liters
 

 

Tags:

Related Products