Products
IEC60309-1 2012 Vehicle Testing Equipment 8 Channels Connector Temperature Rise 0 To 400°C Test System
Products Description
IEC60309-1 2012 8 Channels Connector Temperature Rise 0 To 400°C Test System
Equipment Overview:
The equipment provides a low voltage test voltage to the sample by simulating the normal use environment, and collects the temperature rise within a certain period of time and compares it with the standard requirements.
Structures & Characteristics:
The temperature rise test system consists of a voltage regulator, a current transmitter, a PLC programmable controller, a current transducer, a touch-type human-machine interface and a movable chassis. It can stabilise the output test current, eliminating the effects on the test current due to fluctuations in the supply voltage, changes in the resistance of the connecting wires or copper rods or test samples, and improving the accuracy of the test results. The power supply has the advantages of low loss, high efficiency, easy operation, and complete control and detection functions. The touch screen displays the current value and temperature value of each temperature measurement point at any time. Temperature values are recorded every 2 seconds and a report is generated, which can be stored on a USB stick or copied to a PC for viewing and printing.
Technical Parameters:
Temperature Measurement Point
8 channels
Operation Method
Color humanized touch interface
Output Constant Adjustable Current
AC 0.50~50.00~400.0A(Level 1, can be set)
Output Current Mode
Continuous/ Intermittent
Load Test Output Voltage
Below AC 5V
Current Resolution
0.1A
Ammeter Accuracy
±1%±3 bytes
Voltmeter Accuracy
±1%±3 bytes
Continuous Mode Test Time
0.01~99.99 hours
Intermittent Mode Test Time
0.01~99.99 hours
Intermittent Mode Test Cycles
1~99999 cycles, automatic shutdown when the test cycles reach to the preset value
Temperature Measurement Range
0~400°C, accuracy 0.3% reading + 1°C; resolution: 0.1°C
Temperature Data Acquisition
Configure RS232 communication interface and data record interface
Temperature Scanning Speed
1 to 255 seconds all channels
Temperature Data Record
The data can be stored U disk
Temperature Measuring Thermocouple
OMEGA USA Model T 30AWG Filament Thermocouple, 2 Metres, 8 pcs.
Power Supply
Single phase AC220V±10%, 50/60Hz, 3KVA
Equipment Dimensions and weight
Approx. L 800mm* W 680mm* H1610mm, 125KG
It is used for testing the temperature rise of plugs and sockets of charging ports interface after passing the rated current, assessing the heating of the surface of the electrical accessories when the load current is switched on and whether the temperature rise of the terminals complies with the standard requirements.
Can be used to test electric vehicle charging ports, industrial plugs and sockets and couplers.