IEC60309-1 Clause 20 Vehicle Connector And Plug Breaking Capacity Test Machine

MOQ:1
Price:Negotiable
StandardPackaging:StandardExportingPlywoodCase
DeliveryPeriod:30Days
PaymentMethod:L/C,T/T
SupplyCapacity:20SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KPQC1018

Applied Standard:IEC IEC60309-1

Applied Clause:Clause 20 And 21

Test Station:Single Station

Control Method:Integrated PLC & Touch Screen

Drive Mode:Servo Motor Drive

Linear Stroke:0-100mm

Minimum Order Quantity:1

Price:Negotiable

Packaging Details:Standard Exporting Plywood Case

Delivery Time:30 Days

Payment Terms:L/C, T/T

Supply Ability:20 Sets Per Month

Highlight:Plug Breaking Capacity Test Machine, Connector Plug Breaking Capacity Test Machine, IEC60309-1 Vehicle Testing Equipment


Product Description

 

IEC60309-1 Clause 20 Vehicle Connector and Plug Breaking Capacity Test Machine

 

Product Information:

The Vehicle Connector and Plug Breaking Capacity test machine conforms to the standard requirements of IEC60309-1 clause 20 and clause 21, IEC62196-1 clause 7.11 and clause 7.12 and etc.

It is used to verify whether electrical accessories such as electric vehicle charging interfaces, industrial plugs, socket-outlets and couplers can withstand the mechanical, electrical and thermal stresses that occurred during normal operation without excessive wear or other harmful effects.

 

Technical Parameters:

Applied standard IEC IEC60309-1
Applied clause Clause 20 and 21
Test station Single
Control method PLC intelligent integrated control, with color humanized touch screen
Drive mode Servo motor drive
Sample clamping method Mechanical clamping, the position of clamping point can be adjustable along the 3-axis fixture
Linear stroke 0-100mm, can be preset (the spacing between test plug and test socket≥ 50mm)
Conduction time 0-99.9s, can be preset (electrical contact should be maintained no more than 4s, no less than 2s)
Speed of Insertion and Separation 0-0.85m/s can be preset, default(0.8±0.1)m/s)
Test frequency 0-10 cycles/min, can be preset (3.75cycles/min=7.5 stoke/min)
Test cycles 0~999999 cycles, can be preset
Load power External, providing standard required voltage, current and power factor, the load cabinet is optional
Optional load cabinet Note: only with AC load cabinet, 0-70A, voltage 0-300V
Test contents

Appliance coupler/charging interface breaking capacity test

Appliance coupler / charging interface normal operating life test

Detection function An open circuit alarm can be realized during testing under load, and the cycles can be recorded real in time.
Safety protection Ground protection, short circuit protection
 

 