IEC60529 IPX8 Immersion Test Equipment For Electronic And Electrical Products

MOQ:1
Price:Customized
StandardPackaging:PlywoodCase
DeliveryPeriod:30Days
PaymentMethod:T/T
SupplyCapacity:10SetsPerMonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP4411

Equipment Power Supply:Three Phase AC380V 50Hz 4KW

Pressure Range:0.01~0.50Mpa

Tank Material:SUS304 Stainless Steel

Observation Window:Tempered Glass (thickness: 12mm)

Pressure Sensor Accuracy:0.5 Grade

Control:PLC Control

Minimum Order Quantity:1

Price:Customized

Packaging Details:Plywood Case

Delivery Time:30 Days

Payment Terms:T/T

Supply Ability:10 Sets Per Month

Highlight:IPX8 Immersion Test Equipment, IEC60529 Immersion Test Equipment


Product Description

 

IEC60529 High Quality IPX7 Immersion Test Chamber For Factory Inspection Use

 

Product information:
 

The high pressure water tank is used to verify the protective performance of the enclosure for electronic and electrical products, automobiles, motorcycle parts, household appliances, seals and lamps under continuous immersion in water at degree IPX8 as per IEC 60529:2013.

The water tank is made of stainless steel, the equipment is controlled by PLC, test parameters can be set on the touch screen directly, water supply and pressure are achieved automatically.

 

Technical Parameters:

 

Item

Specifications

Equipment power supply

Three phase AC380V 50Hz 4KW

Small water pump

Brand: South, model no.: CHL2-40, 380VAC, 50Hz, 0.55kw

Protection class: IP55 Insulation class: F

IP code test range

IPX8 test

IPX8 pressure tank

Diameter and height

φ600mm

Full height of the tank is 1500mm (From upper flange point to lower flange point is 1500 mm), the height of tank body is 1200mm

Pressure range

0.01~0.50Mpa

Tank material

SUS304 stainless steel

Pressurization method

Water pressure pressurization, the current pressure value is collected from the PLC from time to time, and the inverter controls the pump speed and frequency to pressurize, and the pressure is constant

Pressure sensor accuracy

0.5 grade

Limit pressure of safety valve protection

0.55 MPa

Pressure protection

a. mechanical protection: spring-type safety relief valve

b. program control: the pressure exceeds the upper limit value, the pump will stop working and immediately release the pressure

Cover opening method

Can be lifted by the screw rod and moved laterally, and can be fully opened for convenient sample placement

Control

PLC control

Test time

Set according to the test standard (range 1-9999 seconds), the unit is: second

Stair

Stainless steel stair

 

 

 
 
 

 

 

Tags:

Related Products