New Energy Vehicles Particular Safety Test System For Whole Vehicle

MOQ:1
Price:Customized
StandardPackaging:Plywood
DeliveryPeriod:30Days
PaymentMethod:L/C,,T/T,WesternUnion,MoneyGram
SupplyCapacity:20setspermonth

Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP1018

Test Sample:New Energy Vehicle

Test Contents:Electrical Safety Test

Equipment Structure:Floor-standing

Test Accuracy:1.5%

Display Mode:19\" LCD

Storage Method:Industrial PC

Minimum Order Quantity:1

Price:Customized

Packaging Details:Plywood

Delivery Time:30 Days

Payment Terms:L/C, , T/T, Western Union, MoneyGram

Supply Ability:20 sets per month

Highlight:1.5% Accuracy Particular Safety Test System, 19\" LCD Particular Safety Test System, GB/T 18487 Particular Safety Test System


Product Description

 

New Energy Vehicles Particular Safety Test System for Whole Vehicle

 
System features:
1. Meet the requirements of automotive-related national and international standards: such as GB/T 18384, GB/T 18487, GB/T 20234, etc.
2. Multi-function in one: AC and DC withstand voltage, charging socket insulation, whole vehicle insulation, insulation resistance monitoring, leakage current, potential equalization, fast charging function, slow charging function.
3. High test accuracy: the basic accuracy of safety testing is 1.5%, and the measurement accuracy of electrical parameters is 0.5%.
4. Record the vehicle VIN number, VSN number and main part number, and print a test result for each vehicle.
5. Bar code recognition, automatic matching, automation, and intelligent testing.
6. Data storage, query and screening, information management.
7. Perfect protection: if the plug is not plugged in, the device will not start high voltage detection; pulling out the plug in the detection state will cut off the power supply to the socket.
8. It can be extended to connect with MES system.

9. 19" LCD display
10. Support customization.

 
Technical Parameters:

Potential Equalization
Test channel 10 channels
Test method/No-load output voltage Four-wire system
Output current setting range DC:1.00~32.00A
Output current accuracy ± (1% of setting+0.20A)
Grounding resistance setting range Upper limit: 0~600mΩ; lower limit: 0~600mΩ; 0=off
Grounding resistance measuring range 0.0~600mΩ
Grounding resistance measuring accuracy ± (1% of reading+3mΩ)
Test time setting range 0.0, 0.1~999.9s 0.0=Continuous output
Test time setting range accuracy ± (1% of setting+0.05s)
Charging Socket Insulation
Output voltage ripple Resistive load, 1000V/1mA, <5%
Output voltage setting range/accuracy DC:100~1000V ccontinuous adjustable
± (1% of setting+3V)
Insulation resistance setting range Upper limit: 0,1~3000MΩ; lower limit: 1~3000MΩ; 0=off
Resistance compensation >30MΩ
Insulation resistance measuring range 0.05~99.99~999.9~3000MΩ
Insulation resistance measuring accuracy 100~499V:0.1 ~2000MΩ:± (5% of reading+2MΩ)
  500~1000V:0.2 ~1000MΩ:± (2% of reading+2digitals)
  1000 MΩ~3000 MΩ:± (5% of reading+2digitals)
Delay time setting range 0.5~999.9s
Test time setting range 0.0, 0.1~999.9s, 0.0= Continuous output
Test time setting accuracy ± (1% of setting+0.05s)
Whole Vehicle Insulation Test
Insulation resistance setting range

Upper limit 0,0.00-100.0MΩ 0=close,

lower limit 0.00- 100 00MΩ

Insulation resistance measurement range 0.20- 100.00MΩ
Insulation resistance measurement accuracy ±(2% reading value + 2 words)
Test time setting range

0.0- 999.9S

0.0=continuous output

Test time setting accuracy ±(0.1% setting value+0.05s)
Insulation Monitoring
Test time setting range

0.0- 999.9S

0.0=continuous output

Test time accuracy ±(0.1% setting value+0.05s)
Judgment type Whether the automotive insulation monitoring is normal and alarm
AC Withstand Voltage
Withstand voltage test type Cold withstand voltage test
Rated output load 200VA (AC: 5000V/40mA )
Output voltage adjustment rate <2% (no load to full load)
Output voltage setting range AC:100-5000V ;50Hz/60Hz
Output voltage accuracy ±(1% setting value+3V)
Breakdown current setting range Upper limit: 0.000-9.999- -40.00mA
Lower limit: 0.000-9.999- -40.00mA 0.000=close
Zero current 0.000-2.000mA
Breakdown current measurement range 0.050- 9.999-40.00mA
Breakdown current measurement accuracy ±(1% of reading value + 5 words)
Rise time/slow down time 0.0-999.9s
Test time setting range

0.0, 0.1-999.9S

0,0=continuous output

Test time setting accuracy ±(0.1% setting value+0.05s)
DC Withstand Voltage
Withstand voltage test type Cold withstand voltage test
Rated output load 60VA (DC: 6000V/10mA )
Output voltage adjustment rate <2% (no load to full load)
Output voltage setting range DC:100-6000V
Output voltage accuracy ±(1% setting value+3V)
Breakdown current setting range

Upper limit: 0.000-9.999-10.00mA;

Lower limit: 0.000-9.999-10.00mA 0.000=off

Zero current 0.000- -2 000mA
Breakdown current measurement range 0.020-9.999-10.00mA
Breakdown current measurement accuracy ±(1% of reading value+0.005mA)
Rise time/slow down time 0.0-999.9s
Test time setting range

0.0, 0.1-999.9S

0.0=continuous output

Test time setting accuracy ±(0.1% setting value+0.05s)
Leakage Current
Leak type setting Static
Output voltage ratio

1.1 times input voltage (output by isolation transformer)/arbitrarily set voltage (output by variable frequency power supply)

 

Output voltage setting range AC:0.0-3000V
Output voltage setting measuring range AC:5.0-300.0V
Output voltage measurement accuracy ±(1% of reading value+3V)
Leakage current setting range

Upper limit: 0.000-5.000mA; Lower limit: 0.000-5.000mA

0.000=off

Zero current 0.000-2.000mA
Leakage current measurement range 0.050-9.999 - 20.00mA
Leakage current measurement accuracy ± (1% of reading value + 5 digits)
Test time setting range

0.0, 0.5-999.9S

0.0=continuous output

Test time setting accuracy (0.1% setting value+0.05s)
Slow Charging Function Detection (Customization)
Voltage setting range AC:0.0-300.0V
Charging current measurement range 0.050-9,999-32.00A
Test time setting range

0-999.9S

0.0=continuous output

Fast Charging Function Detection (Customization)
Charging voltage measurement range DC;0.0-700.0V
Charging current measurement range 0.050-9,999-63.00A
Test time setting range

0.0-999.9S

0.0=continuous output

 
 
 