Battery Testing Equipment / Electrical Appliance Tester 20V 100A For Lithium Battery Charging And Discharging

Battery Testing Equipment / Electrical Appliance Tester 20V 100A For Lithium Battery Charging And Discharging

  • Model:

   Battery Testing Equipment Electrical Appliance Tester 20V 100A For Lithium Battery Charging And Discharging

 

Product Introduction

 

This battery testing system was developed to meet the market demand through many years of continuous innovation. The system is a upgraded version of the Web BTS host computer software It expands the test capabilities to the voltage and temperature of single battery. It also provides DCR function, multi-channels selection, constant power charge functions and so on.

 

Client Invironment

 

 

DEVICECONFIGURATION
CPUPentium dual-core above
CPU speed2.0G above
Memory2G above
Hard DiskSATA interface, 160GB above
File system formatNTFS
OSMicrosoft Windows 2000/XP or above
CD-ROMDVD-ROM
InterfaceUSB, Ethernet Port, RS232 Serial Interface

 

Server Invironment

 

DEVICECONFIGURATION
CPUPentium dual-core above
CPU speed2.0G above
Memory2G above
Hard DiskSATA interface, 500GB above
File system formatNTFS
OSMicrosoft Windows 2000/XP or above
CD-ROMDVD-ROM
InterfaceUSB, Ethernet Port, RS232 Serial Interface
SwitchHuawei H3C
PowerUPS with USB interface

 

Technical Indicators

Set CT4004-20V100A for example:

 

Items

parameters

Input powerAC 380V ±10% / 50Hz
ResolutionAD:16bit; DA:12bit
Input impedance≥1MΩ
sampling frequency10Hz
Channel featuresconstant current source and constant voltage source using a independent double close loop structure
channel control modelIndependently control
VoltageVoltage range of each channelCharge 0.5V~5V; discharge 2.5V~5V
Accuracy±0.1% of range(full range)
Resolution0.3mV
Stability≤0.1%
CurrentCurrent range of each channelCharge 2A~1000A; discharge 2A~1000A
Accuracy±0.1% of range(full range)
Resolution0.06A
stability≤0.1%
PowerDevice power5000W
Resolution0.3W
Stability≤0.2%
TimeCurrent response timeHardware response time when the current change from 0A~1000A: ≤20m
Time range per step≤2000h/step
Resolution1s
Accuracy10-4 s
Data recordRecord conditionTime △t:(1~60000s)
Voltage △U:(5mV~5V)
Current △I:(1000mA~1000A)
Record frequency1Hz
ChargeCharge modeCC charge,CV charge,CC-CV charge
dischargeDischarge modeCC discharge,CP discharge
CycleMeasuring range1~60000 times
Steps per cycle255
loop nestssupport 3 layers
Security protectionProtect by software
  1. data protection in case of power failure

  1. support test offline

  1. can set protection conditions, including: upper voltage, lower voltage, upper current, lower current, time delay

Protect by hardwareadded a protection module for reverse polarity
voltage and current testing sample4-wire connection
Noise≤65dB
Volume36U case,W*D*H 606*606*1790(mm)
 

 

Set CT4004-20V100A auxiliary testing device for example

 

Items

Parameters

TypeVoltage
Temperature
VoltageInput range0V~5V
Accuracy±(0.05% of reading + 0.05% of range)
TemperatureRange﹣25℃~110℃
Accuracy±(1% of reading +1℃)
Resolution0.1℃
Ending conditionAuxiliary voltage ,auxiliary temperature
Conditions of security protectionCan set the security conditions for auxiliary channels, including upper auxiliary voltage, lower auxiliary voltage, upper auxiliary temperature, lower auxiliary voltage
Auxiliary channels in each unit temperature1~32(optional)
Auxiliary channels in each unit voltage1~32(optional)
Unit volume3U case, 482.6*378*130(mm)