EN 50636 Figure 1 Test Finger Probe , Young Adult Arm Probe Nylon Handle Stainless Steel Probe

EN 50636 Figure 1 Test Finger Probe , Young Adult Arm Probe Nylon Handle Stainless Steel Probe

  • Model:

EN 50636 Figure 1 Test Finger Probe Young Adult Arm Probe Nylon Handle Stainless Steel Probe

 

Standard:EN 50636-2-100 figure 1 and IEC 50636-2.

 

Application:It is used to simulate the young adult to test whether the hazardous parts can be touched.

 

Test sample:Hand held power supply operation blower which is used in the garden and vacuum blower and other garden tools

 

Feature:Nylon handle and stainless steel probe

 

Parameters:

 

 

ModelHT-I36
1R5
2Ф10
3R8
4R16
5135°
6410mm
7710mm
8R25
9Ф50

 

 

 

 

Picture for reference:

 

 

 

Standard description

 

Our product of  Test Finger Probe (see Figure 1)shall not to be able to make contact with the hazardous moving parts when it is inserted into the opening up to the entire length of each arm probe.the articulations of each probe shall be manufactured to enable a rotation±90° about the articulations axis.The movements of the joints of each probe shall be free enough to allow easy articulation as the probe is inserted into the opening. Each probe shall be applied with a force not exceeding 20N.

 

Each arm probe shall be twisted and moved in any direction allowed by joints when approaching the hazardous moving parts,If necessary,one or more sections of the machine may be cut away to allow the probe to be configured such that it penetrates as far as possible towards the hazardous moving parts.if a section is removed this shall not allow the probe to penetrate further than it would have done before the removal of the section(s).

The test shall be carried out both with and without the debris collector in place,if the removal of the debris collector causes the power to the fan and/or shredding means to be interrupted,the test shall only be done with the debris collector in place.

 

 

Both arm probe shall not contact the hazardous moving parts.When the test is conduced with the debris collector in place it shall not be possible to push any part of the debris collector into hazardous moving parts.