Gas - Fired Water Heater ( Boiler ) Online Tester Nominal Heat Input Not Exceeding 70KW
Gas - Fired Water Heater ( Boiler ) Online Tester Nominal Heat Input Not Exceeding 70KW
- Model:
Gas - Fired Water Heater ( Boiler ) Online Tester Nominal Heat Input Not Exceeding 70KW
Gas - Fired Water Heater ( Boiler ) Online Tester Nominal Heat Input Not Exceeding 70KW
Instrument Description:
Gas heating water heater (boiler) on-line tester is developed and designed with reference to GB25034-2010, CJ / T228-2006, GB6392 and other technical requirements. It’s applicable for testing the performance of the gas heating water heater (boiler) below 70KW.
Performance and Advantages:
1. High precision, Collocated with the computer and PLC programmable controller, combined with imported sensors for collection, which achieves to accuracy, stable performance and long life.
2. Short response time, the water systems and gas systems of the testing system adopt imported and well-known sensors and solenoid valves, angle seat valve components for controlling, which achieves the quick reaction speed, high stability and other advantages.
3. Design and produce the tester according to the technical requirements of the national standard, and achieve the transmission and transformation between test system and information collected and processed by computer; process operation by friendly human-machine interface and with computer control as the core; a variety of formulas integrated in the computer for automatic control, with the original records storage, easy to query and automatically form a test report form, and can effectively improve the test efficiency.
4. Programmable control, the user can develop the test process, determine the standard, and save the different product test data and projects to facilitate the call to maximize the production efficiency according to their own processing needs.
5. Optional bar code function, enhance product traceability of testing data.
6. Automatic and manual control can change automatically, the system combines auto judgment and manual judgment automatically.
7. Can be remotely released and monitored, through the network to view the detection screen.
Structural Characteristics:
The whole structure is made of aluminum alloy and stainless steel material, all piping is made of SUS304 stainless steel, the structure of the frame of the structure is made of aluminum alloy. The core components are used well-known brands "Air TAC" or imported components to control, accurate accuracy, stable performance, useful life is twice as much as the ordinary tester, It is the necessary testing equipment in the water heater industry.
Test Items:
1. The Water Temperature
2. Return Water Temperature
3. Water Flow
4. Water Pressure
5. Gas Flow
6. Differential Pressure Test
7. Gas Primary Pressure, Secondary Pressure Test
8. The Appliance Operating Voltage, Current
Technical Parameters:
1. Inlet And Outlet Water Temperature Display: Range; 0 ~ 60 ℃, 0 ~ 120 ℃, Accuracy: 0.5 ℃
2. Gas Pressure Display: Range: Primary Pressure: 0 ~ 5000 Pa; Secondary Pressure: 0 ~ 5000 Pa, Accuracy / Minimum Scale: ± 0.5% / 1Pa.
3. Bathroom Water Flow: 0 ~ 20L / Min, Precision / Minimum Scale: ± 1% / 0.1L / Min
4. Heating Water Flow: 0 ~ 30L/ Min, Accuracy / Minimum Scale: ± 1% / 0.1L / Min
5. Gas Flow: 0.04-6 m³ / H, Accuracy / Minimum Scale: ± 1% / 1Pa
6. Inlet Water Pressure: High Pressure: 0.0 ~ 1.6mpa, Low Pressure ~ 1.6mpa, Accuracy: Class 0.5
8. Gas Temperature: 0 ~ 50 ℃, Accuracy: Class 1
9. All the test data can be automatic saved, automatically generate report, esy to query, report format can be designed flexibly.
Inlet And Outlet Water Temperature Display | Range: 0 ~ 60 ℃, 0 ~ 120 ℃, Accuracy: 0.5 ℃ |
Gas Pressure Display | Range: Primary Pressure: 0 ~ 5000 Pa; Secondary Pressure: 0 ~ 5000 Pa, Accuracy / Minimum Scale: ± 0.5% / 1Pa. |
Bathroom Water Flow | 0 ~ 20L / Min, Precision / Minimum Scale: ± 1% / 0.1L / Min |
Heating Water Flow | 0 ~ 30L/ Min, Accuracy / Minimum Scale: ± 1% / 0.1L / Min |
Gas Flow | 0.04-6 m³ / H, Accuracy / Minimum Scale: ± 1% / 1Pa |
Inlet Water Pressure | High Pressure: 0.0 ~ 1.6mpa, Low Pressure ~ 1.6mpa, Accuracy: Class 0.5 |