Ground Recessed Luminaires Light Testing Equipment IEC 60598-2-13

Ground Recessed Luminaires Light Testing Equipment IEC 60598-2-13

  • Model:

Ground Recessed Luminaires Light Testing Equipment IEC 60598-2-13 

 

 

Production introduction:

 

  This test equipment conforms to IEC 60598-2-13 clause 13.6.1 and clause 13.6.2 standard requirements. 

It is used for the ground accessed luminaires static load test and torque test.

  This equipment is controlled by PLC electrical system, the whole operation is controlled on the touch screen, all the parameters can be preset on the touch screen, include every selection mode of the kettle, the touch screen with the functions of manual operation, automatic operation and real-time display.

 

 

Main technical parameters:

 

Power supply380V 50Hz
Test objectground accessed luminaires
Teststatic load test and torque test
Max. load

20KN

Rubber punch

diameter 50mm, thickness 50mm

Maintain time

5-10s for torque test, 1min for static load test

Station

1 station

Standard

IEC 60598-2-13 Clause 13.6.1, 13.6.2

Control

Mitsubishi PLC

Display

Touch screen

 

IEC 60598-2-13 

 

13.6.1 Resistance to static load

Luminaires shall withstand the minimum static load according to the manufacturer's instruction.
13.6.2 Resistance too torque and shear loads
Luminaires designed to be used in areas where motor vehicles may circulate, carriageways, parking areas, etc. shall withstand the forces exerted by a turning, breaking or accelerating tire.

Test details please reference to standard discription.

 

 

Photos