Products Introduction:
The switch plug socket test system consists of one set of switch plug socket test equipment and 2 sets of load boxes. The test system can process breaking testing under load power and endurance testing under normal use for the switches plugs and sockets which are listed in IEC60884-1.
The switch plug socket test equipment is designed and manufactured according to IEC60884-1, IEC61058-1, IEC60669-1standards and etc. It is applicable for household and similar fixed electrical installations’ breaking capacity and normal operation life test, also suitable for testing household and similar usage plug/ socket’s breaking capacity and normal operation life . The purpose is assessing whether the switch is able to withstand the normal use of mechanical damage and electrical fatigue damage, and whether the contact points has adhesion phenomenon, long-term closed or disconnected phenomena, to examine whether the test samples excessive worn and have other harmful consequences. It is special test equipment for switches and plug-sockets electrical endurance test.
The load boxes are designed and manufactured according to IEC60884,IEC61058,IEC606691 standards and etc. It is applicable for household and similar fixed electrical installations switches and plug sockets breaking capacity and normal operation test, the rated voltage of the switch is not greater than 280V and the rated current less than 16A. The purpose is assessing whether the switch is able to withstand the normal use of mechanical damage and electrical fatigue damage, and whether the contacts has adhesion phenomenon, long-term closed or disconnected phenomena, to examine whether the test samples excessive worn and have other harmful consequences.
The test system can do testing for button switches, toggle switches, rocker switches, push switches, rotary switches, plugs and sockets. Coupled with the load (resistive, inductive, capacitive) can process loading test,it has a corresponding control system.
Technical Parameters:
Model | SLT-3 |
Power | AC110V,60Hz or AC220V, 50Hz |
Work station | 6 work stations, three linear stations, three rotary station |
Operation interface | 7 inch color LCD touch screen |
Drive mode | Servo motor |
Control system | PLC |
Test times | 0~999999 times, can be preset |
Conduction time | 0~999.9s, can be preset |
Break time | 0~999.9s, can be preset |
Test angle | 0-360°, can be preset |
Numbers of test angles | Angle 1~15 , can be preset |
Test stroke | Linear: 0 ~ 100mm, adjustable |
Test speed | Linear: 10 ~ 200mm/s, adjustable |
Test environment | Atmospheric pressure 80 ~ 106kpa; |
Dimensions | L*W*H=1260mmx800mmx600mm |
Weight | 125KG |
Model | HT-LDC |
Meter Power | Single phase with ground AC220 ± 10% / 50Hz or AC110 ± 10% / 60Hz |
Load Power | Three-phase four-wire AC380 ± 10% / 50Hz. |
Voltage V | Range 0 ~ 300V accuracy ± 05% ± 2d |
Current A | Range 0 ~ 40A accuracy ± 05% ± 2d |
Power KW | Range 0~12KW,accuracy±05% |
Power Factor | Range 03 to 0999 accuracy ± 05% ± 2d |
Load Selection | Resistive, Inductive and Capacitive load three in one, switchable |
Capacitance Selection | 70uf,140uf,73uf optional |
Output Mode | Each power,Interval power optional |
Count/Preset | 0~999999 times, can be preset |
Load power capacity | 3*10KVA |
Output current limit | 30A,the load will be automatically cut off when over 32A |
Output voltage limit | 300V,the load will be automatically cut off when over 305V |
Atmospheric pressure | 80~106kpa |
Ambient temperature | 5~40°C |
Relative humidity | (20~90)%RH |
Use environment | Requires no violent shaking, no vibration, no electromagnetic |
Dimensions and weight | L*W*H=1200*760*1830mm,800kg |