Product Information:
This device is designed according to the IEC60320-1,clause 18.2 figure 13 standard requirements . It is used for testing the heat resistance of coupler in hot conditions and very hot conditions, this device adopts temperature control, precise display and durable.
Technical Parameters:
Model No. | TR-4 |
Standard | IEC60320-1 clause 18.2 and figure 13 |
Power Supply | AC120V, 50Hz or AC220V, 60HZ |
Coupler inlets (as below): | |
10A heat resistance appliance inlet | Test 10A connector, test temperature 120℃ ± 2℃ |
10A very hot resistance appliance inlet | Test 10A connector, test temperature 155℃± 2℃ |
16A very hot resistance appliance inlet | Test 16A connector, test temperature 155℃ ± 2℃ |
Test temperature | 0-200℃, can be preset |
Test time | 0-99 hours and 59 minutes, can be preset |
Coupler center distance | Uniform arrangement byΦ175 circular |