IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine
IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine
- Model:
IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine
IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine
Product information:
The HT Apparatus for impact test at low temperature confirms to the standard of IEC60884 figure 27 and figure 42. The first one is fit for impact test of wire while the latter one is applied for the impact test of plug, socket, switch, wire and electrical conduit.
Standard: IEC 60884-1 2013 clause 24.4, 30.4, figure 27 and 42, IEC60811-1-4, VDE0620 and so on
Application: This device is use for checking the impact resistance at low temperature of electrical accessories, as well as wires and cables.
Test sample: Electrical accessories, surface type mounting boxes, screw glands, covers, wires and cables etc.
Feature: This device should be used with low temperature chamber, the device should be placed on the sponge rubber pad of about 40mm thick, and should be put in the low temperature chamber before and during the test.
Technical parameters:
Model | Impact test apparatus H926 | Impact test apparatus H926A |
Station | Single station | Three stations |
Weight of the impact hammer (g) | 1000±2 and 100±1 | 100, 200, 300, 400, 500, 600, 750, 1000, 1250, 1500(See table 1 and 2) |
Height of the impact (mm) | 100 | 100 |
Steel intermediate piece | Φ20, bottom end rounded R300, 100g | Φ20, bottom end rounded R300, 100g |
Standard | IEC60884-1 24.4 Figure 27 IEC60884-1 30.4 Figure 42 | IEC60811-1-4 |
Operation | Manual, mechanical release | Manual, mechanical release |
Table1 For power cables for fixed installation, the mass of the hammer for testing the samples shall be as given in the following table:
Overall diameter (mm) | Mass of hammer (g) | |
Above | Up to and including | |
- | 4.0 | 100 |
4.0 | 6.0 | 200 |
6.0 | 9.0 | 300 |
9.0 | 12.5 | 400 |
12.5 | 20.0 | 500 |
20.0 | 30.0 | 750 |
30.0 | 50.0 | 1000 |
50.0 | 75.0 | 1250 |
75.0 | - | 1500 |
Table 2 For flexible cables and cords and telecommunication cables, the mass of the hammer for testing the sample shall be as follows:
Overall diameter (mm) | Mass of hammer (g) | |
Above | Up to and including | |
For flat cords | 100 | |
- | 6.0 | 100 |
6.0 | 10.0 | 200 |
10.0 | 15.0 | 300 |
15.0 | 25.0 | 400 |
25.0 | 35.0 | 500 |
35.0 | - | 600 |