Products
Single Station Vehicle Testing Equipment Non - Rewireable Accessories Mechanical Strength Flexing Test
Products Description
Vehicle Non-rewireable Accessories Mechanical Strength 90° Flexing Testing Apparatus
Standards & Clauses:
IEC62196-1: 2014 “Plug, socket-outlets, vehicle connectors and vehicle inlets–Conductive charging of electric vehicle-Part1: General requirements” clause 26.4, figure 14
IEC60309-1: 2012 “Plug, socket-outlets and couplers for industrial purposes–Part1: General requirements” clause 24.4, figure 9
Samples and Restrictions:
Electric vehicle charging interfaces (plug, socket-outlets, vehicle connectors), industrial purpose plugs, socket-outlets and couplers.
Application:
Used to process the mechanical load flexing test of the vehicle plugs, socket-outlets and couplers non-rewireable accessories.
Test Principle:
Adopts the servo motor to drive the turntable, to make the specimen to swing left and right, the test will be automatically stopped when the test cycles reach the preset value.
Structure:
The device is driven by a servo motor, with mounting aluminum plate for large size samples, it can realize that the oscillation axis matches the cord entering point as much as possible when clamping the sample, thereby achieving a minimum lateral displacement of the flexible cable and load.
Dimensions & Weight:
Power supply: AC220V±10%,50/60Hz, power 3KW, or match client’s local power supply requirements
Dimensions: about W1000*D800*H1600mm
Weight: about 150kg
Technical Parameters:
Test Station
Single
Electrical Control Method
PLC intelligent integrated control, 7-inch humanized touch interface operation
Drive Mode
Servo motor
Sample Clamping Method
Mechanical clamping, the position of clamping point is adjustable
Flexing Angle
0-360° can be adjusted freely (default 90°, 45°on either side of the vertical)
Flexing Rate
0-60 cycles / min, can be preset
Flexing Cycles
0~999999 can be preset, default 20000 cycles
Load Weights
20N, 25N, 50N, 75N, 100N
Load Power
External, load cabinet with adjustable voltage between conductors 0-250V and current AC0-400A adjustable is optional
Test Judgment
Judging by the signals given when the current is conducting or not