Products Description

Place of Origin:China

Brand Name:KingPo

Certification:Calibration Certificate (Cost Additional)

Model Number:KP7711

Flame:225W & 500W

Control:Mitsubishi PLC

Test Volume:4m³

Ignition Process:Automatic

Chamber Material:Stainless Steel

Temperature Measurement Range:MAX 1100°C

Minimum Order Quantity:1

Price:Negotiation

Packaging Details:Plywood

Delivery Time:1 Month

Payment Terms:L/C, T/T, Western Union, MoneyGram

Supply Ability:20 Sets Per Month

Highlight:flame test chamber, flammability testing equipment


Product Description

UL 1581 Electrical Cables Wires 225W 500W Flame VW1 FT2 4m³ Flammability Test Chamber

 

Overview:

 

This flammability test chamber meets the requirements of UL1581 flame test. The effects of flames in the early stages of fire on electrical and electronic products are used to assess the degree of fire hazard through simulation techniques. It is mainly used for 1080 VW-1 (vertical-specimen) flame test and 1100 horizontal-specimen/ FT2 flame test on finished wires and cables or cords, to evaluate the ability of wires, cables or flexible cords to spread flame to nearby flammable materials when it is on fire.

 

The equipment adopts PLC control system, touch screen humanized operation interface, black background, multi-function flame gauge; the chamber body is made of stainless steel, the observation window is large; the original imported flame control system to make the flame adjustment become simple; and it has stable performance and convenient operation.

 

Techinicals:

 

Flames 225W&500W
Standard UL1581
Power Supply 220V/ 50Hz or 110V/60Hz (can be customized)
Operation system Mitsubishi PLC control, VEINVIEW7” touch screen
Ignition Process Automatic
Burner Diameter: 9.5mm ± 0.5mm, Length:100mm, Original imported, in line with ASTM 5025 standard
Burning Angles 0°, 20°, 45° adjustable
Flame Height 20mm~125mm±1mm adjustable
Timing Device 9999X0.1s can be preset
Thermocouple U.S. original Omega Φ0.5mm armored stainless steel sheathed K-type thermocouple
Temperature Measurement Distance 25±1mm/55±1mm
Temperature Measurement Range MAX 1100°C
Flame Test

Adopt original imported flowmeter, the flow rate is adjustable, the accuracy is 1%, the following are the reference values of each test:

500W: 965±30ml/min, 54±2S(100-700°)

Reference values of UL1581 power, flame height, temperature measurement time and flow:

225W: (16.5mm)/84±2S 405 ±10mL/min& 45±5 mm water

500W: 125mm(40mm)/54±2S

A: 965 ±30mL/min&125±25 mm water

B: 385 ±15mL/min&552±100 mm water

C: 300 ±10mL/ min&600±125 mm water

Copper Weight

Ф9mm±0.01mm Copper head,Cu-ETP purity:99.96%,

10 ± 0 .05 g

Gas Category Methane
Test Space 4m³
Chamber and Appearance Stainless steel chamber, black matt background with exhaust fan
Size and weight W*D*H=1.7*1.3*2.4m, about 350kg
 
Features:
  • Mitsubishi PLC control and  VEINVIEW7” touch screen opetaion, ensure the operation is humanized
  • Original imported flame control system to make the flame adjustment become simple
  • Automatic ingition process to ensure the operator's safety
  • Original imported flowmeter and  Omega themocouple ensures the testing accuracy

 
 
 